OBJECTIVE The purpose of this study was to clarify the usefulness of 99mTc-sestamibi (MIBI) delayed imaging in the assessment of the severity of myocardial ischemia in patients with coronary artery stenosis. METHODS Forty-three angina pectoris with coronary stenosis of greater than 75% were enrolled in this study. Myocardial perfusion SPECT images were obtained 1 and 6 hours after an intravenous injection of MIBI at rest. Stress myocardial perfusion SPECT images were also acquired after the injection of MIBI. And myocardial fatty acid metabolism images were obtained 30 minutes after the injection of BMIPP at rest. Myocardial perfusion SPECT images were divided into 20 segments which were semiquantitatively assessed according to a 4-level defect score scale: score 0 (normal) to score 3 (severely); then the extent score (ES) and severity score (SS) were calculated. RESULTS The sensitivity for myocardial ischemia showed the highest rate at 88.3% with MIBI delayed SPECT. According to the coronary angiography findings, MIBI stress SPECT and MIBI delayed SPECT detected the severity and extent of ischemia with more sensitivity than MIBI early SPECT in 12 patients (group A) with stenosis of more than 75% but less than 90% (p < 0.01). Even though MIBI stress SPECT detected the severity and extent of ischemia in 31 patients (group B) with stenosis of more than 90% but less than 100%, there was no significant difference between MIBI stress SPECT and MIBI delayed SPECT. BMIPP SPECT revealed significant differences between group A and group B regarding the severity of myocardial ischemia. MIBI reverse redistribution was observed in 33 patients and no significant difference existed between groups A and B. CONCLUSIONS Myocardial washout of MIBI was frequently observed in patients with angina pectoris and the detection accuracy for ischemia was high. MIBI imaging is considered useful for assessment not only of myocardial perfusion but also mitochondrial function. The imagings with BMIPP and delayed MIBI could serve to determine the severity of myocardial ischemia more accurately.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Cardiac Mitochondrial Function by a Nuclear Imaging Technique using Technetium-99m-MIBI Uptake Kinetics

Mitochondria play an important role in energy production for the cell. The proper function of a myocardial cell largely depends on the functional capacity of the mitochondria.  Therefore it is necessary to establish a novel and reliable method for a non-invasive assessment of mitochondrial function and metabolism in humans. Although originally designed for evaluating myocardial perfusion, 99mTc...

متن کامل

Enhanced regional washout of technetium-99m-sestamibi in patients with coronary spastic angina.

BACKGROUND Reverse redistribution and rapid washout of 99mTc-sestamibi are observed in patients with acute myocardial infarction and may indicate viable myocardium. However, the clinical significance of this phenomenon has not been rigorously examined in other cardiac diseases. Thus, we investigated whether reverse redistribution and washout of 99mTc-sestamibi could be used in the diagnosis and...

متن کامل

Utility of 99mTc-Sestamibi SPECT/CT in the Early Localization of Metastatic Parathyroid Carcinoma

Parathyroid carcinoma is very rare, with only a few documented cases. Hence, metastatic lesions are infrequently documented on scintigraphic imaging. We present a case of a 63-year-old female presenting with elevated serum levels of ionized calcium and parathyroid hormone (PTH) who was referred to our department for a parathyroid scan with SPECT/ CT. Parathyroid scintigraphy showed a focus of i...

متن کامل

Determination of Uterus Absorbed Dose by Patients following Myocardial Perfusion Scan using TLD and Conjugate View Methods

Introduction: The determination of patient’s absorbed dose is the first step of radiation protection which depends on the quantification of organ activity in nuclear medicine. The aim of the present study was to determine the absorbed dose by patient’s uterus following myocardial perfusion scan with 99mTC-sestamibi using Theroluminescnce dosimetry (TLD) and conjugate-view metho...

متن کامل

Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease.

UNLABELLED This study was designed to compare the tracer kinetics between 99mTc-sestamibi and 99mTc-tetrofosmin in a heterogeneous group of 24 patients admitted for routine perfusion imaging. METHODS Twelve patients were studied with 99mTc-tetrofosmin and 12 with 99mTc-sestamibi. In each group, six patients had a low likelihood for coronary artery disease, and six patients had angiographicall...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 20 5  شماره 

صفحات  -

تاریخ انتشار 2006