Evaluating the effect of pupil dilation on spectral-domain optical coherence tomography measurements and their quality score
نویسندگان
چکیده
BACKGROUND Spectral-domain optical coherence tomography (SD-OCT) provides fast scan speed and high scan resolution improving its diagnostic accuracy. The purpose of this study was to evaluate if SD-OCT measurements and their quality score are influenced by pupil dilation. METHODS Retinal nerve fiber layer thickness (RNFL), ganglion cell complex (GCC) and optic nerve head (ONH) were measured in one eye of 57 glaucoma patients and 36 healthy subjects using spectral domain optical coherence tomography (SD-OCT) before and after pupil dilation. Comparisons were made between measurements and their quality score pre- and post dilation (Signal Strength Index, SSI). Overall RNFL, average GCC and ONH rim volume were considered in the analysis. RESULTS No statistically significant differences were found between pre- and post-dilation measurements in both groups (glaucoma: RNFL 80 ± 15 μm vs 80 ± 16 μm, p = 0.87; GCC 81.35 ± 13.4 μm vs 81.10 ± 13.14 μm, p = 0.92; ONH 0.05 ± 0.11 mm(3) vs 0.04 ± 0.07 mm(3), p = 0.74; controls RNFL 99 ± 12 μm vs 98 ± 14 μm, p = 0.70; GCC 92.12 ± 6.7 μm vs 91.54 ± 7.05 μm, p = 0.72; ONH 0.11 ± 0.1 mm(3) vs 0.04 ± 0.07 mm(3), p = 0.36) nor between pre- and post-dilation quality score (glaucoma SSI RNFL 54.3 ± 10.3 vs 51.7 ± 18.1, p = 0.12; SSI GCC 58 ± 9.5 vs 57 ± 8.09, p = 0.55; SSI ONH 48.5 ± 7.6 vs 46.6 ± 7.2, p = 0.16; controls SSI RNFL 57 ± 10.3 vs 54 ± 9.31, p = 0.2; SSI GCC 60.9 ± 8.1 vs 58.8 ± 7.3, p = 0.3; SSI ONH 51.5 ± 8.9 vs 50.4 ± 8.3, p = 0.59). CONCLUSION Pupil dilation doesn't affect SD-OCT measurements and their quality score.
منابع مشابه
بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک
Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...
متن کاملReproducibility of Optical Coherence Tomography Retinal Nerve Fiber Layer Thickness Measurements Before and After Pupil Dilation
PURPOSE To evaluate the intra- and interobserver reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness measurements before and after pupil dilation using spectral-domain optical coherence tomography (SD-OCT). METHODS In this observational case series, 44 eyes of 44 healthy subjects were scanned by two trained operators on the same day, using Cirrus SD-OCT (Carl Zeiss Med...
متن کاملRetinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography
Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...
متن کاملComparison of Physiologic versus Pharmacologic Mydriasis on Anterior Chamber Angle Measurements Using Spectral Domain Optical Coherence Tomography
Purpose. To compare the effects of physiologic versus pharmacologic pupil dilation on anterior chamber angle (ACA) measurements obtained with spectral domain optical coherence tomography (SD-OCT). Methods. Forty eyes from 20 healthy, phakic individuals with open angles underwent anterior segment OCT imaging under 3 pupillary states: (1) pupil constricted under standard room lighting, (2) physio...
متن کاملInfluence of Cataract Surgery on Measurements of Spectral Domain Optical Coherence Tomography
INFLUENCE OF CATARACT SURGERY ON MEASUREMENTS OF SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY Bambo et al evaluated the effect of uncomplicated cataract phacoemulsification on the measurements of macular and retinal nerve fibre layer (RNFL) using two spectral domain (SD) optical coherence tomography (OCT) instruments-Cirrus OCT (Zeiss) and Spectralis OCT (Heidelberg)-in 60 eyes healthy subjects...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2015