Planar Quadrature RF Transceiver Design Using Common-Mode Differential-Mode (CMDM) Transmission Line Method for 7T MR Imaging

نویسندگان

  • Ye Li
  • Baiying Yu
  • Yong Pang
  • Daniel B. Vigneron
  • Xiaoliang Zhang
چکیده

The use of quadrature RF magnetic fields has been demonstrated to be an efficient method to reduce transmit power and to increase the signal-to-noise (SNR) in magnetic resonance (MR) imaging. The goal of this project was to develop a new method using the common-mode and differential-mode (CMDM) technique for compact, planar, distributed-element quadrature transmit/receive resonators for MR signal excitation and detection and to investigate its performance for MR imaging, particularly, at ultrahigh magnetic fields. A prototype resonator based on CMDM method implemented by using microstrip transmission line was designed and fabricated for 7T imaging. Both the common mode (CM) and the differential mode (DM) of the resonator were tuned and matched at 298MHz independently. Numerical electromagnetic simulation was performed to verify the orthogonal B1 field direction of the two modes of the CMDM resonator. Both workbench tests and MR imaging experiments were carried out to evaluate the performance. The intrinsic decoupling between the two modes of the CMDM resonator was demonstrated by the bench test, showing a better than -36 dB transmission coefficient between the two modes at resonance frequency. The MR images acquired by using each mode and the images combined in quadrature showed that the CM and DM of the proposed resonator provided similar B1 coverage and achieved SNR improvement in the entire region of interest. The simulation and experimental results demonstrate that the proposed CMDM method with distributed-element transmission line technique is a feasible and efficient technique for planar quadrature RF coil design at ultrahigh fields, providing intrinsic decoupling between two quadrature channels and high frequency capability. Due to its simple and compact geometry and easy implementation of decoupling methods, the CMDM quadrature resonator can possibly be a good candidate for design blocks in multichannel RF coil arrays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Common mode volume coil design for in vivo MR imaging at 7T

Introduction The volume coil is a well-established coil which creates homogeneous B1 field and MR images (1). In order to yield homogenous B1 field distribution, sufficient coupling among the resonant elements (rungs) of a volume coil is necessary. Although the coupling could be improved by reducing the distances between the coil elements, increasing the dimension and number of the coil element...

متن کامل

Resonant Mode Reduction in Radiofrequency Volume Coils for Ultrahigh Field Magnetic Resonance Imaging

In a multimodal volume coil, only one mode can generate homogeneous Radiofrequency (RF) field for Magnetic Resonance Imaging. The existence of other modes may increase the volume coil design difficulties and potentially decreases coil performance. In this study, we introduce common-mode resonator technique to high and ultrahigh field volume coil designs to reduce the resonant mode while maintai...

متن کامل

Shielded Microstrip Head Array at 7T

INTRODUCTION Microstrip transceiver arrays have been demonstrated to provide higher efficiency on signal excitation/reception and low mutual coupling and have become a popular RF solution to parallel MR imaging at ultrahigh fields in humans [1,2]. In most designs, the ground planes of microstrips are separated (Fig 1) to minimize their mutual coupling [1-5]. Practically, due to space limitation...

متن کامل

RF-safe intravascular imaging using a self-visualizing transformer line

Objective: Intravascular MR-imaging may provide a local SNR gain possibly relevant for some interventional and diagnostic applications like high resolution intravascular imaging. However, regular signal transmission lines are not RF-safe due to possible RF heating of leads by resonant excitation of common mode currents. This safety issue prohibits intravascular MR imaging coils from being used ...

متن کامل

Single-feed quadrature coils as transceiver array elements for improved SNR and transmit efficiency

INTRODUCTION: Quadrature or circularly polarized (CP) coils are desired in MR experiments due to their improved MR sensitivity (by 40%) and reduced excitation power (by half) compared with linear coils. This is particularly true in parallel imaging and parallel excitation where the reception/excitation acceleration demands highly efficient receive and transmit. Conventionally quadrature coils a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013