Hand-Eye Calibration without Hand Orientation Measurement Using Minimal Solution

نویسندگان

  • Zuzana Kukelova
  • Jan Heller
  • Tomás Pajdla
چکیده

In this paper we solve the problem of estimating the relative pose between a robot’s gripper and a camera mounted rigidly on the gripper in situations where the rotation of the gripper w.r.t. the robot global coordinate system is not known. It is a variation of the so called hand-eye calibration problem. We formulate it as a problem of seven equations in seven unknowns and solve it using the Gröbner basis method for solving systems of polynomial equations. This enables us to calibrate from the minimal number of two relative movements and to provide the first exact algebraic solution to the problem. Further, we describe a method for selecting the geometrically correct solution among the algebraically correct ones computed by the solver. In contrast to the previous iterative methods, our solution works without any initial estimate and has no problems with error accumulation. Finally, by evaluating our algorithm on both synthetic and real scene data we demonstrate that it is fast, noise resistant, and numerically stable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Light fields for minimal invasive surgery using an endoscope positioning robot.

OBJECTIVES To generate a fast and robust 3-D visualization of the operation site during minimal invasive surgery. METHODS Light fields are used to model and visualize the 3-D operation site during minimal invasive surgery. An endoscope positioning robot provides the position and orientation of the endoscope. The a priori un-known transformation from the endoscope plug to the endoscope tip (ha...

متن کامل

Hand–eye calibration using a target registration error model

Surgical cameras are prevalent in modern operating theatres and are often used as a surrogate for direct vision. Visualisation techniques (e.g. image fusion) made possible by tracking the camera require accurate hand-eye calibration between the camera and the tracking system. The authors introduce the concept of 'guided hand-eye calibration', where calibration measurements are facilitated by a ...

متن کامل

Eye-hand-workspace calibration using laser pointer projection on plane surface

Purpose – The purpose of this paper is to propose a calibration method that can calibrate the relationships among the robot manipulator, the camera and the workspace. Design/methodology/approach – The method uses a laser pointer rigidly mounted on the manipulator and projects the laser beam on the work plane. Nonlinear constraints governing the relationships of the geometrical parameters and me...

متن کامل

Hand-Eye Calibration Using Dual Quaternions

To relate measurements made by a sensor mounted on a mechanical link to the robot’s coordinate frame, we must first estimate the transformation between these two frames. Many algorithms have been proposed for this so-called hand-eye calibration, but they do not treat the relative position and orientation in a unified way. In this paper, we introduce the use of dual quaternions, which are the al...

متن کامل

Calibration-Free Hand-Eye Calibration: A Structure-from-Motion Approach

The paper presents an extended hand-eye calibration approach that, in contrast to the standard method, does not require a calibration pattern for determining camera position and orientation. Instead, a structure-from-motion algorithm is applied for obtaining the eye-data that is necessary for computing the unknown hand-eye transformation. Different ways of extending the standard algorithm are p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012