Fluoroscopy procedure and equipment changes to reduce staff radiation exposure in the interventional spine suite.

نویسندگان

  • Chris Plastaras
  • Malathy Appasamy
  • Yusef Sayeed
  • Coleen McLaughlin
  • Jeremy Charles
  • Anand Joshi
  • Donald Macron
  • Bryan Pukenas
چکیده

BACKGROUND Fluoroscopic guided percutaneous interventional spine procedures are increasingly performed in recent years as they have been shown to be target specific and enhance patient safety. However, ionizing radiation has been associated with stochastic effects such as cancer and genetic defects as well as deterministic effects such as cataracts, erythema, epilation, and even death. These are dose related, and hence, measures should be taken to minimize radiation exposure to patients and health care personnel to reduce these adverse effects. OBJECTIVE A risk reduction project was completed with the goal of reducing effective doses to the staff and patients in a university-based spinal interventional practice. Effective dose reduction to the staff and patients was hypothesized to occur with technique and equipment changes in the procedure suite. The goal of this study was to quantify effective dose rates to staff before and after interventions. STUDY DESIGN Retrospective study comparing descriptive data of effective dose to the health care staff before and after implementation of a combination of technique and equipment changes. METHODS Technique changes from pre to post intervention period included continuous needle advancement under continuous fluoroscopic controlled by the interventional physician to intermittent needle advancement under pulsed fluoroscopic controlled by the radiology technician. Equipment changes included circumferential lead drape skirt around the procedure table and use of mobile transparent lead barriers on both sides of the procedure table.Effective dose exposure measured in Millirem (mrem) from the radiation dosimetry badges for pre-intervention (February 2009 through June 2009) and post-intervention (November 2009 through March 2010) periods were examined through monthly radiation dosimetry reports for the fluoroscopy suite staff. RESULTS A total of 685 interventional procedures were performed in the pre-intervention period and 385 in the post-intervention period. The median cumulative mrem (interquartile range) for all staff combined in the pre-intervention period was 71 (28,75) and post-intervention period was 1 (0,3). The median mrem per procedure was significantly higher in the pre-intervention group 0.46 (0.36, 0.54) compared to post-intervention 0.01 (0.0.03); P < 0.01. The percentage reduction in overall effective dose per procedure to all staff was 97.3%. LIMITATIONS Observational study, multiple radiation reduction interventions confound the individual effects of each intervention's effective dose CONCLUSIONS Spinal injection technique and equipment changes in the procedure suite significantly reduced the rate of effective dose to the clinical staff.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recommendations for occupational radiation protection in interventional cardiology.

The radiation dose received by cardiologists during percutaneous coronary interventions, electrophysiology procedures and other interventional cardiology procedures can vary by more than an order of magnitude for the same type of procedure and for similar patient doses. There is particular concern regarding occupational dose to the lens of the eye. This document provides recommendations for occ...

متن کامل

Occupational health risks in interventional cardiology: expected inherent risk or preventable personal liability?

SEE PAGE 616 A lthough advances have been made in the diagnosis of and therapy for cardiovascular disease, this has not come without risks. This risk includes a 3-fold increase in patient medical radiation exposure over the past 25 years (1), with all imaging areas challenged to reduce patient dose (2). Although interventional cardiology contributes a small component to this increase, when a cu...

متن کامل

Radiation Exposure to the Surgeon and Patient During a Fluoroscopic Procedure: How High Is the Exposure Dose? A Cadaveric Study.

STUDY DESIGN Using fresh cadavers, real-time dosimeters were used to estimate the radiation exposure dose from C-arm fluoroscopy to surgeons, medical staff, and patients during various procedures. OBJECTIVE The aim of this study was to evaluate the radiation exposure dose from C-arm fluoroscopy, which is used to generate real-time images of the human body, under a variety of conditions and in...

متن کامل

Radiation exposure during percutaneous nephrolithotomy; Is there a risk of the patient and the operating team?

Background: The aim of this study was to calculate the radiation amount exposed during percutaneous nephrolithototomy (PCNL) and to make the urologists and other staff sensitive about the radiation risk they were exposed to. Materials and Methods: We measured the radiation exposure during 114 cases of PCNL performed. Thermoluminescent dosimeters (TLD) were placed between the operation table and...

متن کامل

Radiation exposure to anaesthetists during interventional radiology.

This prospective study determined the level of radiation exposure of anaesthetists during interventional radiological procedures performed in the endoscopic retrograde cholangiopancreatography suite and cardiac catheterisation laboratory and compared it with the current safety guidelines. Anaesthetists wore area-specific lithium fluoride thermo-luminescent dosimeter badges at standardised posit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pain physician

دوره 16 6  شماره 

صفحات  -

تاریخ انتشار 2013