Closure of patent ductus arteriosus with oversized Amplatzer occluder in a patient with pulmonary hypertension

نویسندگان

  • Hekim Karapınar
  • Zekeriya Kucukdurmaz
  • Mehmet Burhan Oflaz
  • İbrahim Gül
  • Ahmet Yılmaz
چکیده

Diagnosis of patent ductus arteriosus is rare in adulthood. Closure of ductus is difficult when diagnosed at an adult age due to the development of pulmonary hypertension and pulmonary arterial disease that generally occurs. Closure of the ductus might be contraindicated, as it may lead to deterioration of the pulmonary arterial perfusion or to a pulmonary hypertensive crisis. In addition, another risk associated with percutaneous closure for these patients is the risk of embolism of the asymmetrically shaped device to the systemic circulation. We present in this manuscript a case with patent ductus arteriosus diagnosed at an adult age that underwent successful closure by the percutaneous method. During closure, an oversized Amplatzer duct occluder device was used to reduce the risk of device embolism.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Forceps Retrieval of an Embolized Amplatzer Duct Occluder

Transcatheter closure of patent ductus arteriosus with the Amplatzer duct occluder shows excellent results. However, there is a risk of device embolization after deployment. We report the case of a 33-year-old man in whom an embolized Amplatzer device was retrieved from the right pulmonary artery by a percutaneous method. We also review this uncommon severe complication and offer technical tips...

متن کامل

Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder.

AIM To evaluate whether transcatheter closure with the Amplatzer duct occluder offers an alternative to surgical treatment in infants with a persistent ductus arteriosus. METHODS 12 patients under 1 year of age (age 1-11 months, body weight 2.6-8.7 kg) with clinical and echocardiographic findings of a significant duct were considered for transcatheter closure with the Amplatzer occluder. The ...

متن کامل

Evaluating the Clinical Course of Patent Ductus Arteriosus after Discharge and Comparing in Therapies Techniques

Background Patent ductus arteriosus is an open channel between the aorta and pulmonary artery. The study aimed to evaluate the clinical course of patent ductus arteriosus after discharge and comparing in therapies technique. Materials and Methods This cross-sectional and inferential- descriptive study was performed in the hospitals of city of Zahedan-Iran in the period of one decade from 2005 ...

متن کامل

[Right patent ductus arteriosus with an ipsilateral aortic arch: percutaneous closure with amplatzer devices].

The association of a right aortic arch with an ipsilateral patent ductus arteriosus is rare, especially when there are no other intracardiac anomalies. We report three female patients aged 26, 35 and 9 years with this combination in whom previous attempts at surgical closure by thoracotomy and sternotomy were unsuccessful and who subsequently underwent successful percutaneous closure of the def...

متن کامل

Use of an Amplatzer Vascular Plug to occlude a tubular type of patent ductus arteriosus

Patent ductus arteriosus (PDA) is a common congenital heart defect. All PDAs, regardless of size or degree of symptoms, require occlusion. Transcatheter PDA occlusion features fewer complications than trans-thoracic closure. It is also more cost-effective and has an excellent occlusion rate. Therefore, transcatheter PDA occlusion is accepted as the standard treatment option for PDA. However, tu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2013