Inert gas diffusion method for measurement of blood flow using saturation techniques. Comparison with directly measured blood flow in isolated gastrocnemius muscle of the cat.

نویسندگان

  • P Sejrsen
  • K H Tonnesen
چکیده

The isolated gastrocnemius muscle of the cat was used to study the relation between the desaturation of xenon measured by external monitoring, and blood flow measured directly by a dropcounter. The metered blood flow agreed with that calculated from the initial slope of the desaturation curve from tissue equilibrated by prolonged intra-arteria] infusion and also by atraumatic gas labelling of a local area of the muscle (approximately 0.15% of the muscle weight). In this sense the concept of uniform distribution of blood flow in skeletal muscle has received substantial support. The identity of the results obtained by local gas labelling and by intra-arterial equilibration of the whole muscle with gas implies that there is, at least initially, diffusion equilibrium between tissue and blood in both. However, the clearance curves could in no instance be fitted by a single exponential function. This indicates that the diffusion equilibrium is not maintained after the initial phase. It is suggested that this is not due to the presence of anatomical arteriovenous shunts or other types of uneven perfusion, but to counter current exchange of inert gas through the walls of vessels, i.e. shunting by diffusion explains the shape of the desaturation curves. ADDITIONAL

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inert gas diffusion method for measurement of blood flow. Comparision of bolus injection to directly measured blood flow in the isolated gastrocnemius muscle.

The isolated cat gastrocnemius preparation was used to study the relation between the washout of Xenon measured by external monitoring and blood flow measured directly by a dropcounter. The experimental possibility was thereby tested of recording the total tracer bolus and its subsequent washout by external monitoring, using the height H and the corresponding area A of the washout curve. The pa...

متن کامل

Human cerebral blood flow measured by two inert gas techniques. Comparison of the Kety-Schmidt method and the intra-arterial injection method.

Two inert gas methods for measurement of tissue blood flow were compared. The two methods are (1) Kety and Schmidt's inert gas saturation method, in which the tissue saturation is followed by detecting the concentration of the tracer in the venous blood leaving the organ and (2) the intraarterial radioactive inert gas injection method where the tissue washout is measured by detecting the residu...

متن کامل

Muscle metabolism with blood flow restriction in chronic fatigue syndrome.

The purpose of this study was to determine whether chronic fatigue syndrome (CFS) is associated with reduced blood flow and muscle oxidative metabolism. Patients with CFS according to Centers for Disease Control criteria (n = 19) were compared with normal sedentary subjects (n = 11). Muscle blood flow was measured in the femoral artery with Doppler ultrasound after exercise. Muscle metabolism w...

متن کامل

Comparison of the Effects of Resistance Training with Blood Flow Restriction and Traditional Resistance Training on Myostatin, Muscle Mass and some Physiological Factors in Middle-Aged Women: A Clinical Trial

    Background and Objectives: The response of myostatin to resistance training with blood flow restriction is not perfectly clear. Therefore, the purpose of this study comparing the effects of eight weeks resistance training with blood flow restriction and traditional resistance training on myostatin, muscle mass and some related-muscle physiological factors in middle-aged women. Materials ...

متن کامل

Tissue blood flow measurement by laser Doppler technique

  Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 1968