Electron Impact Excitation Cross Sections of Xenon for Optical Plasma Diagnostic
نویسنده
چکیده
منابع مشابه
Optical electron polarimetry with heavy noble gases.
We have measured the polarization of fluorescence emitted by the noble gases He, Ne, Ar, Kr, and Xe following impact excitation by polarized electrons. In He, the 3P→2S transition was studied; in the heavy noble gases the np(n11)p D3→np(n11)s P2 transitions were analyzed. We investigated these transitions as candidates for efficient optical electron polarimetry and found that, because of their ...
متن کاملAbsolute Cross Sections of Multi-Photon Ionization of Xenon by the Comparison with Process of its Electron-Impact Ionization
Comparison of electronand photon-impact processes as a method for determination of photo-ionization cross sections is described, discussed and shown to have many attractive features. Keywords—Transition probability, cross section, photoionization, electron-ionization, multi-photon process.
متن کاملLow-energy electron-impact excitation of the 3,1A2(n--> pi *) states of formaldehyde.
A three-state calculation of electron-impact excitation of formaldehyde to the a ' A 2 and A ' A 2 states is carried out using the Schwinger multichannel variational method. The integral and differential cross sections so obtained agree fairly well with theoretical results obtained using the complex Kohn method. Though agreement between the calculated integral cross section and the single avail...
متن کاملSystematic comparison of positron - and electron - impact excitation of the 3 vibrational mode of CF
Absolute measurements are presented for the excitation of the 3 vibrational mode in CF4 by positron and electron impact from 0.1 to 2 eV. To minimize systematic differences, these measurements were made using the same trap-based electron or positron beam, associated experimental apparatus, and procedures. Unlike other vibrational excitation cross sections studied to date, the near-threshold cro...
متن کاملCompare charged and uncharged particles leakage of plasma focus for medical radioisotopes production
In this study, to calculate the radioactivity of radioisotopes such as 11C, 15O, 18F and 123,124I in a focus plasma device for the production of medical radioisotopes, the particles of neutrons and protons with cubic targets of Nitrogen, Xenon, Carbon and a solid natural Boron is used. Particles energy are at the input of the program from 1MeV to 10MeV. Also, the total yield coefficient is cons...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007