Automated enzymatic method for determining ammonia in plasma, with 14-day reagent stability.

نویسندگان

  • W E Neeley
  • J Phillipson
چکیده

This is an automated, cost-efficient enzymatic method for determining ammonia in plasma. In most assays for ammonia the reagents are stable for only one or two days at 4 degrees C, but the reagents in our method are stable for at least 14 days. Our method was developed for use with a Cobas-Fara analyzer but can be easily adapted to other automated analyzers. It is essential to use closed sample vials. Our results, obtained at much less cost, correlate well with those by the Du Pont aca method. Precision studies gave the following results: within-run (n = 20 each), for x = 46 mumol/L, SD = 0.7 mumol/L, CV = 1.6%, and for x = 593 mumol/L, SD = 4.0 mumol/L, and CV = 0.7%; day-to-day precision during a year: for x = 47.7 mumol/L, SD = 2.4 mumol/L, CV = 5.0% (n = 360); and for x = 643 mumol/L, SD = 20.5 mumol/L, and CV = 3.2% (n = 365). The standard curve was linear to 1000 mumol of NH3 per liter.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated enzymatic method for the determination of ammonia: application to rumen fluid, gut fluid, and plasma.

The enzymatic method for the determination of ammonia with glutamate dehydrogenase has been adapted to the AutoAnalyzer. The automated method was applicable for NH(3) measurement in sheep rumen samples, swine gut fluid samples, and bovine plasma. Results were compared with those of the Conway diffusion method and the manual enzymatic method. The automated method allows 30 samples per h to be an...

متن کامل

Enzymatic rate assay of creatinine in serum and urine.

A two-step method for assaying creatinine in serum and urine samples, suitable with automated analyzers, is reported. Reagent 1, for the first step, contains a blanking system [creatine amidinohydrolase (CRTase), urease, glutamate dehydrogenase, NADPH, and 2-oxoglutarate] and a NADPH-regenerating system [Mg(2+)-dependent isocitrate dehydrogenase (ICD), MgCl2, and excess isocitrate]. Reagent 2, ...

متن کامل

Automated enzymatic assay for plasma ammonia.

An enzymatic method for determining plasma ammonia with the Du Pont Automatic Clinical Analyzer (aca) is described. The assay requires a sample volume of 500 muL for a kinetic ammonia measurement. The reaction is initiated with glutamate dehydrogenase and the rate of depletion of NADPH is monitored with two measurements, 17 s apart, at 340 nm. Reaction conditions have been optimized for maximum...

متن کامل

Modified micro-scale enzymatic method for plasma ammonia in newborn and pediatric patients; comparison with a modified cation-exchange procedure.

We modified two "kit" procedures for plasma ammonia to make them suitable for use with newborn and pediatric patients. Available methods either require too large a specimen, are insufficiently sensitive in the normal range, or are too cumbersome. One was an enzymatic (Sigma Chemical Co., St. Louis, Mo. 63178), the other a cation-exchange (Hyland, Costa Mesa, Calif. 92626) method. The modified m...

متن کامل

Kinetic enzymatic method for automated determination of HDL cholesterol in plasma.

A sensitive fixed-time kinetic enzymatic method for the measurement of high density lipoprotein cholesterol is described, as adapted for the Cobas Bio centrifugal analyser (Hoffmann LaRoche). The Boehringer Mannheim cholesterol esterase/cholesterol oxidase/peroxidase/3,4-dichlorophenol kinetic reagent was modified by the inclusion of 2,4,6-tribromo-3-hydroxybenzoic acid which reacts with hydrog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 34 9  شماره 

صفحات  -

تاریخ انتشار 1988