Free-breathing myocardial perfusion MRI using SW-CG-HYPR and motion correction.

نویسندگان

  • Lan Ge
  • Aya Kino
  • Mark Griswold
  • James C Carr
  • Debiao Li
چکیده

First-pass perfusion MRI is a promising technique to detect ischemic heart disease. Sliding window (SW) conjugate-gradient (CG) highly constrained back-projection reconstruction (HYPR) (SW-CG-HYPR) has been proposed to increase spatial coverage, spatial resolution, and SNR. However, this method is sensitive to respiratory motion and thus requires breath-hold. This work presents a non-model-based motion correction method combined with SW-CG-HYPR to perform free-breathing myocardial MR imaging. Simulation studies were first performed to show the effectiveness of the proposed motion correction method and its independence from the pattern of the respiratory motion. After that, in vivo studies were performed in six healthy volunteers. From all of the volunteer studies, the image quality score of free breathing perfusion images with motion correction (3.11 ± 0.34) is improved compared with that of images without motion correction (2.27 ± 0.32), and is comparable with that of successful breath-hold images (3.12 ± 0.38). This result was further validated by a quantitative sharpness analysis. The left ventricle and myocardium signal changes in motion corrected free-breathing perfusion images were closely correlated to those observed in breath-hold images. The correlation coefficient is 0.9764 for myocardial signals. Bland-Altman analysis confirmed the agreement between the free-breathing SW-CG-HYPR method with motion correction and the breath-hold SW-CG-HYPR. This technique may allow myocardial perfusion MRI during free breathing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial Perfusion MRI Using SW-CG-HYPR in Canines with Improved Spatial Coverage, Resolution and SNR

SW-CG-HYPR and the conventional methods. The delineation of the myocardial territories supplied by LCX stenoses in SW-CG-HYPR images is clearly improved as compared to the reference images. Figure 3. Comparison of the signal changes vs. time curves between SW-CG-HYPR and reference methods in a dog study. Figure 1. Schematic of the perfusion data acquisition structure: (a) Conventional SR prepar...

متن کامل

Myocardial perfusion MRI with SW-CG-HYPR: a comparison to conventional SR-Turbo-FLASH and x-ray angiography in patients with suspected coronary artery disease

In the current study, we prospectively compared the diagnostic value of SW-CG-HYPR and conventional SRTurbo-FLASH for myocardial perfusion MRI in patients with suspected CAD. Compared with conventional SRTurbo-FLASH, SW-CG-HYPR allows increased spatial coverage (whole left ventricular coverage), improved temporal and spatial resolution and SNR, reduced motion artifacts and has higher diagnostic...

متن کامل

Three-Dimensional Myocardial Perfusion MRI Using SW-CG-HYPR

Introduction: First-pass perfusion MRI is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, SNR, and cardiac motion related image artifacts. Parallel imaging methods have been applied in myocardial perfusion MRI, but the spatial coverage and SNR remain limited. Time-resolved data acquisitio...

متن کامل

Myocardial perfusion MRI using SW-CG-HYPR for the detection of coronary artery disease

In this work, we have prospectively examined the diagnostic value of adenosine-induced stress myocardial perfusion MRI using SW-CG-HYPR in 50 patients with suspected CAD. Using the high-resolution, whole left ventricle SW-CG-HYPR method, perfusion MRI was able to depict hemodynamically relevant coronary artery stenosis with an accuracy of 90% and 93% based on perpatient and per-vessel analyses,...

متن کامل

Adenosine-induced stress myocardial perfusion MRI using SW-CG-HYPR with whole left ventricular coverage: comparison of results with X-ray angiography in patients with suspected CAD

Results The prevalence of CAD was 55%. In the per-patient analysis, the sensitivity, specificity and accuracy of SW-CG-HYPR myocardial perfusion imaging were 95%, 83% and 90%, respectively. In the per-vessel analysis, these values were 98%, 89% and 93%, respectively. Figure 1 illustrates the detection of significant CAD by SW-CG-HYPR myocardial perfusion imaging with correlation to X-ray corona...

متن کامل