One-hour radioimmunoassay of serum drug concentrations, as exemplified by digoxin and gentamicin.
نویسندگان
چکیده
Double-antibody radioimmunoassays in which tritium is used for labeling have been adapted for emergency determinations of serum drug concentrations. In the cases of digoxin and gentamicin, the first and second antibody incubations may be carried on simultaneously, minimizing incubation times (10 and 27 mm, respectively). Counting the bound radioactivity in solubilized immunospecific precipitates decreases variability in the composition of the phase counted and markedly decreases problems of quenching and chemiluminescence. Logitlog transformation of the sigmoidal standard curve results in a straight line, which can be described by its slope and intercept and which remains constant if assay conditions and critical reagents are held constant. Because the slope and intercept of the standard curve are characteristic of a given assay system, it is possible to calculate the theoretical standard curve for a specific assay system by using the means of previously observed slopes and intercepts. Thus, a separate standard curve need not be prepared for each subsequent assay run. Total time required for drug determinations is now less than 1 h. When unknown samples were measured by both the conventional radioimmunoassay method and the new rapid radioimmunoassay method, the values correlated well (r = 0.99) for both digoxin and gentamicin.
منابع مشابه
Assessment of Abnormal Serum Digoxin Concentration
ABSTRACT Cardiac glycosides have been used in the management of heart failure for more than 200 years and remain the only drug currently available for Long-term ambulatory use that have positive inotropic effect. The relatively narrow therapeutic- index of cardiac glycosides renders them particularly difficult to use, and the clinician should have a detailed understanding of the actions and ph...
متن کاملTherapeuticDrugsExemplifiedby GentamicinDeterminationin HumanSerum
We applied a homogeneous reactant-labeled fluorescent immunoassay to the measurement of therapeutic drug concentrations in human serum, exemplified here by gentarnicin. A derivative of umbelliferyl-3-galactoside was coupled covalently to the drug and this conjugate was found to be nonfluorescent under assay conditions. The drug/dye conjugate was a substrate for bacterial /3-galactosidase and yi...
متن کاملMicroencapsulated antibodies in radioimmunoassay--I. Determination of digoxin.
We describe the application of the microencapsulated-antibody technique to the radioimmunoassay of digoxin in serum. Droplets of emulsified rabbit antibody are microencapsulated in a semipermeable nylon membrane by an interfacial polymerization technique. The antibody microcapsules are incubated with 125I-labeled digoxin and unlabeled digoxin for 15 min at 37 degrees C, then free and bound digo...
متن کاملAutomated particle-counting immunoassay for digoxin.
We describe a non-radioisotopic automated immunoassay for serum digoxin in the therapeutic range at 50 samples per hour by use of the particle-counting immunoassay technique and a special reagent, rheumatoid factor. Digoxin is determined by evaluating its inhibitory activity on the agglutination of digoxin-coated latex particles. The agglutinating system consists of the anti-digoxin IgG mixed w...
متن کاملSerum , Atrial , and Urinary Digoxin Levels During Cardiopulmonary Bypass in Children By RICHARD
Serum, urine, and tissue samples were collected from 42 children undergoing open-heart surgery and analyzed for digoxin by radioimmunoassay. Of these, 24 had been digitalized prophylactically (RECENT) and 18 had been receiving maintenance therapy (MAINT) for one month or longer. Twenty-five percent of the RECENT patients exhibited arrhythmias during the postoperative period as compared to none ...