LED Fluorescence Microscopy for the Diagnosis of Pulmonary Tuberculosis: A Multi-Country Cross-Sectional Evaluation

نویسندگان

  • Luis Eduardo Cuevas
  • Najla Al-Sonboli
  • Lovett Lawson
  • Mohammed Ahmed Yassin
  • Isabel Arbide
  • Nasher Al-Aghbari
  • Jeevan Bahadur Sherchand
  • Amin Al-Absi
  • Emmanuel Nnamdi Emenyonu
  • Yared Merid
  • Mosis Ifenyi Okobi
  • Juliana Olubunmi Onuoha
  • Melkamsew Aschalew
  • Abraham Aseffa
  • Greg Harper
  • Rachel Mary Anderson de Cuevas
  • Sally Jane Theobald
  • Carl-Michael Nathanson
  • Jean Joly
  • Brian Faragher
  • Stephen Bertel Squire
  • Andrew Ramsay
چکیده

BACKGROUND The diagnosis of tuberculosis (TB) in resource-limited settings relies on Ziehl-Neelsen (ZN) smear microscopy. LED fluorescence microscopy (LED-FM) has many potential advantages over ZN smear microscopy, but requires evaluation in the field. The aim of this study was to assess the sensitivity/specificity of LED-FM for the diagnosis of pulmonary TB and whether its performance varies with the timing of specimen collection. METHODS AND FINDINGS Adults with cough ≥2 wk were enrolled consecutively in Ethiopia, Nepal, Nigeria, and Yemen. Sputum specimens were examined by ZN smear microscopy and LED-FM and compared with culture as the reference standard. Specimens were collected using a spot-morning-spot (SMS) or spot-spot-morning (SSM) scheme to explore whether the collection of the first two smears at the health care facility (i.e., "on the spot") the first day of consultation followed by a morning sample the next day (SSM) would identify similar numbers of smear-positive patients as smears collected via the SMS scheme (i.e., one on-the-spot-smear the first day, followed by a morning specimen collected at home and a second on-the-spot sample the second day). In total, 529 (21.6%) culture-positive and 1,826 (74.6%) culture-negative patients were enrolled, of which 1,156 (49%) submitted SSM specimens and 1,199 (51%) submitted SMS specimens. Single LED-FM smears had higher sensitivity but lower specificity than single ZN smears. Using two LED-FM or two ZN smears per patient was 72.8% (385/529, 95% CI 68.8%-76.5%) and 65.8% (348/529, 95% CI 61.6%-69.8%) sensitive (p<0.001) and 90.9% (1,660/1,826, 95% CI 89.5%-92.2%) and 98% (1,790/1,826, 95% CI 97.3%-98.6%) specific (p<0.001). Using three LED-FM or three ZN smears per patient was 77% (408/529, 95% CI 73.3%-80.6%) and 70.5% (373/529, 95% CI 66.4%-74.4%, p<0.001) sensitive and 88.1% (95% CI 86.5%-89.6%) and 96.5% (95% CI 96.8%-98.2%, p<0.001) specific. The sensitivity/specificity of ZN smear microscopy and LED-FM did not vary between SMS and SSM. CONCLUSIONS LED-FM had higher sensitivity but, in this study, lower specificity than ZN smear microscopy for diagnosis of pulmonary TB. Performance was independent of the scheme used for collecting specimens. The introduction of LED-FM needs to be accompanied by appropriate training, quality management, and monitoring of performance in the field. TRIAL REGISTRATION Current Controlled Trials ISRCTN53339491. Please see later in the article for the Editors' Summary.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه ارزش تشخیصی اسمیر خلط به دو روش میکروسکوپی در بیماران مشکوک به سل ریوی با و بدون استفاده ازهیپوکلریت سدیم

Background and purpose: Direct smear microscopy is the most common method of detecting tuberculosis with 70% sensitivity in best conditions, therefore, researches have always focused on improving the sensitivity of sputum smear. This study aimed at comparing the diagnostic value of sputum smear using light microscopy and fluorescence microscopy without sodium hypochlorite in patients with suspe...

متن کامل

Usefulness of light emitting diode (LED) fluorescent microscopy as a tool for rapid and effective method for the diagnosis of pulmonary tuberculosis.

BACKGROUND Tuberculosis remains world's leading cause of death from a single infectious agent. Fluorescence microscopy offers well-described benefits, comparing with brightfield microscopy, for the evaluation sputum smear samples for tuberculosis. We evaluated the diagnostic performance of fluorescence microscopy, using novel Light Emitting Diode (LED) technology as an alternative to the conven...

متن کامل

Led Fluorescence Microscopy: Leads the Future of Rapid and Effective Pulmonary Tuberculosis Diagnosis

Early diagnosis and appropriate treatment play an important role in combating the mortality and morbidity caused by Tuberculosis and a rapid, reliable microscopy that can detect acid fast bacilli can be a very useful diagnostic modality. We have evaluated the performance of Light Emitting Diode Fluorescence Microscopy as an alternative to the existing conventional methods in the diagnosis of Pu...

متن کامل

حساسیت MTB-PCR خون در تشخیص مایکوباکتریوم توبرکلوزیس

Background: Tuberculosis is still one of the most important causes of mortality and morbidity in many countries and is the second only to human immunodeficiency virus as a cause of death worldwide resulting from a single infectious agent. In 1993, the World Health Organization declared tuberculosis a global public health emergency. Conven-tional methods for the diagnosis of Mycobacterium tuberc...

متن کامل

Time Delay and Associated Factors in Diagnosis and Treatment of Pulmonary Tuberculosis in Markazi Province

Introduction: Delay in the diagnosis of tuberculosis increases the risk of death and enhances the transmission of disease in the community. This study aims to determine the patient and health service delay and factors affecting it in tuberculosis diagnosis. Materials & Methods: A cross-sectional survey that included all the public health centers was conducted in Markazi province from March 200...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2011