Dosimetric assessment of a novel metal artifact reduction method in CT images

نویسندگان

  • Maria F. Spadea
  • Joost Verburg
  • Guido Baroni
  • Joao Seco
چکیده

The aim of this study was to assess the ability of metal artifact reduction (MAR) algorithm in restoring the CT image quality while correcting the tissue density information for the accurate estimation of the absorbed dose. A phantom filled with titanium (low-Z metal) and Cerrobend (high-Z metal) inserts was used for this purpose. The MAR algorithm was applied to phantom's CT dataset. Static intensity-modulated radiation therapy (IMRT) plans, including five beam angles, were designed and optimized on the uncorrected images to deliver 10 Gy on the simulated target. Monte Carlo dose calculation was computed on uncorrected, corrected, and ground truth image datasets. It was firstly verified that MAR methodology was able to correct HU errors due to the metal presence. In the worst situation (high-Z phantom), the image difference, uncorrected ground truth and corrected ground truth, went from -4.4 ± 118.8 HU to 0.4 ± 10.8 HU, respectively. Secondly, it was observed that the impact of dose errors estimation depends on the atomic number of the metal: low-Z inserts do not produce significant dose inaccuracies, while high-Z implants substantially influence the computation of the absorbed dose. In this latter case, dose errors in the PTV region were up to 23.56% (9.72% mean value) when comparing the uncorrected vs. the ground truth dataset. After MAR correction, errors dropped to 0.11% (0.10% mean value). In conclusion, it was assessed that the new MAR algorithm is able to restore image quality without distorting mass density information, thus producing a more accurate dose estimation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Method for Metal Artifact Reduction in CT Scan Images

Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...

متن کامل

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Dosimetric impact of orthopedic metal artifact reduction (O‐MAR) on spine SBRT patients

The dosimetric impact of orthopedic metal artifact reduction (O-MAR) on spine SBRT patients has not been comprehensively studied, particularly with spinal prostheses in high-dose gradient regions. Using both phantom and patient datasets, we investigated dosimetric effects of O-MAR in combination of various metal locations and dose calculation algorithms. A physical phantom, with and without a t...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013