Accurate spectroscopic calibration for noninvasive glucose monitoring by modeling the physiological glucose dynamics.
نویسندگان
چکیده
The physiological lag between blood and interstitial fluid (ISF) glucose is a major challenge for noninvasive glucose concentration measurements. This is a particular problem for spectroscopic techniques, which predominantly probe ISF glucose, creating inconsistencies in calibration, where blood glucose measurements are used as a reference. To overcome this problem, we present a dynamic concentration correction (DCC) scheme, based on the mass transfer of glucose between blood and ISF, to ensure consistency with the spectral measurements. The proposed formalism allows the transformation of glucose in the concentration domain, ensuring consistency with the acquired spectra in the calibration model. Taking Raman spectroscopy as a specific example, we demonstrate that the predicted glucose concentrations using the DCC-based calibration model closely match the measured glucose concentrations, while those generated with the conventional calibration methods show significantly larger deviations from the measured values. In addition, we provide an analytical formula for a previously unidentified source of limiting uncertainty arising in spectroscopic glucose monitoring from a lack of knowledge of glucose kinetics in prediction samples. A study with human volunteers undergoing glucose tolerance tests indicates that this lag uncertainty, which is comparable in magnitude to the uncertainty arising from noise and nonorthogonality in the spectral data set, can be reduced substantially by employing the DCC scheme in spectroscopic calibration.
منابع مشابه
Improving the robustness of multivariate calibration models for the determination of glucose by near-infrared spectroscopy
Near-infrared spectroscopy has proven to be one of the most promising techniques for the development of a noninvasive blood glucose monitoring system for diabetic patients. In this work, Fourier transform infrared (FT-IR) transmission measurements of the combination band region (4000 – 5000 cm) were analyzed for samples containing glucose (analyte) in a matrix of bovine serum albumin and triace...
متن کاملRecent advances in noninvasive glucose monitoring
The race for the next generation of painless and reliable glucose monitoring for diabetes mellitus is on. As technology advances, both diagnostic techniques and equipment improve. This review describes the main technologies currently being explored for noninvasive glucose monitoring. The principle of each technology is mentioned; its advantages and limitations are then discussed. The general de...
متن کاملModeling of Calibration Effectiveness and Blood-to-Interstitial Glucose Dynamics as Potential Confounders of the Accuracy of Continuous Glucose Sensors during Hyperinsulinemic Clamp.
BACKGROUND Models of the dynamics of interstitial fluid-based continuous glucose sensors imply a variable sensor deviation from reference blood glucose (BG), depending on both sensor calibration procedure and BG dynamics. These effects could have a significant effect on the cross-interpretation of nonidentical accuracy studies. METHODS Hyperinsulinemic euglycemic and hypoglycemic clamps were ...
متن کاملA novel noninvasive blood glucose monitor.
OBJECTIVE To evaluate the precision and accuracy of a new advanced prototype of a noninvasive blood glucose monitor across a wide range of serum glucose concentrations. RESEARCH DESIGN AND METHODS An advanced handheld noninvasive glucose monitor prototype was calibrated and tested using patients recruited by the General Research Center of the University of Connecticut Health Center. The monit...
متن کاملA Spectroscopic System for Near Infrared Glucose Measurement
Noninvasive blood glucose monitoring has been long envisioned to serve as an invaluable tool in the treatment of diabetes. The current invasive method makes it difficult for diabetic patients to perform frequent blood glucose measurements and maintain better control of their glucose levels, crucial in reducing the risks of complications. In this thesis, the use of the near infrared absorption s...