The effects of abnormal blood pressure on arterial sampler filling times.

نویسندگان

  • Aaron L Cortes
  • Chelsea M Dalessandro
  • Tina M Glade
  • Sophia Af Shirdon
  • Jen J Uhlir
  • F Herbert Douce
چکیده

BACKGROUND Sampler filling time begins with the initial flash of blood in the needle hub until the preset sampler volume is obtained. Previous studies have shown statistically significant differences between arterial and venous sampler filling times, but included only a few subjects with abnormal blood pressures. OBJECTIVE To determine whether the time required to fill a vented arterial sampler is an accurate indication of a successful arterial blood sample in adults with abnormal blood pressure. We hypothesized that mean arterial pressure and arterial sampler filling time would have a negative correlation, and that venous sampler filling time would be significantly longer than arterial filling time. METHODS We studied 40 subjects: 25 arterial subjects, and 15 venous subjects. The arterial subjects included 3 groups: hypertensive, hypotensive, or normal. During the arterial and venipuncture procedures, we measured sampler filling time and recorded blood volume. The PO2 of the samples was measured. Additionally, blood pressure and SpO2 were measured in the arterial group. RESULTS The mean sampler filling time was 220.4 s/mL for the venous group, and 18.1 s/mL for all 3 arterial groups combined. There were significant differences between each mean arterial sampler filling rate and mean venous filling rate (P < .001). There were no significant differences in mean sampler filling rate between the arterial subgroups (P > .99). The correlation between mean arterial pressure and filling rates was 0.06 (P = .38). CONCLUSIONS There is a significant difference between arterial and venous filling rates. There was no relationship between filling time and abnormal mean arterial pressure. Regardless of the arterial pressure, the arterial sampler filling time can be used as an indicator of a successful arterial puncture at the bedside.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arterial sampler filling time during arterial and venous punctures, and its relationship with mean arterial pressure in human subjects.

BACKGROUND When obtaining an arterial blood sample via percutaneous puncture, there is a risk of accidentally obtaining venous blood. Conventional methods of confirming arterial blood at the bedside, such as blood color and pulsatile return, can be misleading in patients with low blood pressure or hypoxemia. OBJECTIVE To determine if the arterial sampler filling time can be an accurate indic...

متن کامل

Comparison of sampler filling times among selected arterial blood samplers.

BACKGROUND True arterial blood samples are essential in making clinical decisions for respiratory patients. Previous studies using only the Portex Pro-Vent arterial sampler have shown a significant difference between arterial and venous filling times. The goal of this study was to determine whether there is a statistically significant difference between sampler filling times measured at a norma...

متن کامل

Effects of mean arterial pressure and needle size on arterial sampler filling time.

BACKGROUND Arterial blood sampling is subject to numerous pre-analytical errors, one of which is inadvertent venous blood sampling. Especially when assessing oxygenation and titrating ventilation, accidental venous blood sampling may lead to inappropriate respiratory care and repeated percutaneous punctures. OBJECTIVE To determine the effects of mean systemic blood pressure and needle size on...

متن کامل

Comparing Effects of Listening to Nature Sounds and Lavender Inhalation on Hemodynamic Parameters among Patients Undergoing Cataract Surgery with Regional Anesthesia: A Randomized Controlled Trial

Background and purpose: Candidates for cataract surgery have high anxiety and worry for various reasons which may cause changes in their hemodynamic parameters. Maintaining hemodynamic stability during anesthesia and surgery is very important. This study aimed at comparing the effects of listening to nature sounds and lavender inhalation on hemodynamic parameters in patients undergoing cataract...

متن کامل

Synthesis of Novel 4-[1-(4-fluorobenzyl)-5-imidazolyl] Dihydropyridines and Studying their Effects on Rat Blood Pressure

Objective(s) Calcium-channel blockers have an important role in the treatment of several cardiovascular disorders. Derivatives of 1, 4-dihydropyridine are one of the most potent calcium antagonists. In this study four novel ', 4-dihydropyridine calcium channel blockers were synthesized and their hypotensive properties were investigated in male rats. Materials and Methods Four 1, 4-dihydropyr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 58 11  شماره 

صفحات  -

تاریخ انتشار 2013