Beat-to-beat stroke volume estimation from aortic pressure waveform in conscious rats: comparison of models.

نویسندگان

  • C Cerutti
  • M P Gustin
  • P Molino
  • C Z Paultre
چکیده

Several methods for estimating stroke volume (SV) were tested in conscious, freely moving rats in which ascending aortic pressure and cardiac flow were simultaneously (beat-to-beat) recorded. We compared two pulse-contour models to two new statistical models including eight parameters extracted from the pressure waveform in a multiple linear regression. Global as well as individual statistical models gave higher correlation coefficients between estimated and measured SV (model 1, r = 0.97; model 2, r = 0.96) than pulse-contour models (model 1, r = 0.83; model 2, r = 0.91). The latter models as well as statistical model 1 used the pulsatile systolic area and thus could be applied to only 47 +/- 17% of the cardiac beats. In contrast, statistical model 2 used the pressure-increase characteristics and was therefore established for all of the cardiac beats. The global statistical model 2 applied to data sets independent of those used to establish the model gave reliable SV estimates: r = 0.54 +/- 0.07, a small bias between -8% to +10%, and a mean precision of 7%. This work demonstrated the limits of pulse-contour models to estimate SV in conscious, unrestrained rats. A multivariate statistical model using eight parameters easily extracted from the aortic waveform could be applied to all cardiac beats with good precision.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single-beat determination of preload recruitable stroke work relationship: derivation and evaluation in conscious dogs.

OBJECTIVES To derive and evaluate a method of estimating the slope (Mw) of the preload recruitable stroke work (PRSW) relationship between left ventricular stroke work (SW) and end-diastolic volume (EDV) from a single beat. BACKGROUND Mw is a load-insensitive index of contractile function, but its clinical application has been limited by the need to record multiple beats over a wide volume ra...

متن کامل

Cardiac output and stroke volume estimation using a hybrid of three models

Cardiac output (CO) and stroke volume (SV) are the key hemodynamic parameters to be monitored and assessed in ambulatory and critically ill patients. The purpose of this study was to introduce and validate a new algorithm to continuously estimate, within a proportionality constant, CO and SV by means of mathematical analysis of peripheral arterial blood pressure (ABP) waveforms. The algorithm c...

متن کامل

Continuous determination of beat to beat stroke volume from aortic pressure pulses in the dog.

Present methods for measurement of stroke volume from the aortic pressure pulse are not suitable for beat-to-beat determinations during non-steady state conditions because these methods assume that each systolic ejection is equal to the peripheral runoff during the same beat. We have tested a new method which allows determination of an aortic pressure-volume conversion factor over a wide range ...

متن کامل

Continuous Stroke Volume Estimation from Aortic Pressure Using Zero Dimensional Cardiovascular Model: Proof of Concept Study from Porcine Experiments

INTRODUCTION Accurate, continuous, left ventricular stroke volume (SV) measurements can convey large amounts of information about patient hemodynamic status and response to therapy. However, direct measurements are highly invasive in clinical practice, and current procedures for estimating SV require specialized devices and significant approximation. METHOD This study investigates the accurac...

متن کامل

Novel, single-beat approach for determining both end-systolic pressure–dimension relationship and preload recruitable stroke work

OBJECTIVE The end-systolic pressure-dimension relationship (ESPDR) and the preload recruitable stroke work (PRSW) relationship are load-insensitive measures of contractility, but their clinical application has been limited by the need to record multiple beats over a wide volume range. In this study, we therefore sought to validate a new method to concomitantly determine the ESPDR and the PRSW r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 281 3  شماره 

صفحات  -

تاریخ انتشار 2001