Pulmonary vein imaging: comparison of 3D magnetic resonance angiography with 2D cine MRI for characterizing anatomy and size.

نویسندگان

  • Mushabbar A Syed
  • Dana C Peters
  • Haroon Rashid
  • Andrew E Arai
چکیده

Pulmonary vein imaging is integral for planning atrial fibrillation ablation procedures. We tested the feasibility of quantifying pulmonary vein ostial diameter using two-dimensional cine cardiac magnetic resonance (2D cine CMR) and three-dimensional magnetic resonance angiography (3D MRA). Nine patients with a history of atrial fibrillation and 20 normal volunteers underwent 2D cine CMR and contrast-enhanced 3D MRA of pulmonary veins on a 1.5 T scanner. Pulmonary vein ostial diameters were measured and pulmonary vein vessel border sharpness was graded qualitatively. Both techniques provided excellent pulmonary vein imaging; however, 3D MRA was faster to perform. The average difference between the systolic and diastolic pulmonary vein diameter was 2.5 mm (23.2%, p < 0.0001) in normal volunteers and 2.2 mm (16.9%, p < 0.0001) in atrial fibrillation patients. The ostial diameter measurements by 3D MRA were significantly larger than on 2D cine CMR. Additionally, the pulmonary vein borders appeared sharper with 2D cine CMR compared to 3D MRA. In conclusion, the 2D images can resolve differences in diameter across the cardiac cycle, while the 3D images provide high quality anatomical depiction but blur borders due to pulsatile motion. We suggest a protocol combining 2D cine CMR and 3D MRA for comprehensive evaluation of pulmonary veins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Respiratory-Triggered (RT) 3D cine steady-state free precession cardiac mri with standard 2D cine imaging and magnetic resonance angiography in Congenital Heart Disease (CHD)

Background This is a pilot study to evaluate the performance of whole-heart isotropic RT-3D cine SSFP sequence as an efficient single solution for assessment of morphology and function in CHD by comparing it to: 1. Short axis (SA) 2D cine SSFP for LV volumetry and function 2. Multiplanar 2D cine SSFP for intracardiac morphology 3. Cine 2D SSFP and gadolinium (Gd)-enhanced 3D MRA for aortic root...

متن کامل

Whole-heart cine MRI using real-time respiratory self-gating.

Two-dimensional (2D) breath-hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three-dimensional (3D) cardiac MR can overcome some of these problems because it requires minimal planning and can be reformatted in any plane. However, current methods,...

متن کامل

Selective pulmonary venous flow visualization and quantification by flow-sensitive four-dimensional cine magnetic resonance imaging facilitates and improves the accurate diagnosis of partial anomalous pulmonary venous drainage

Methods In six patients with echocardiographically suspected PAPVD, anatomy was evaluated using standard magnetic resonance imaging including angiography. Functional analysis included shunt calculations from standard flowmeasurements. Furthermore, 4D VEC MRI was used for visualization of maldraining pulmonary veins and quantification of flow via the maldraining veins and interatrial communicati...

متن کامل

Ultrafast three-dimensional contrast-enhanced magnetic resonance angiography and imaging in the diagnosis of partial anomalous pulmonary venous drainage.

OBJECTIVES The purpose of our study was to evaluate patients with suspected anomalous pulmonary veins (APVs) and atrial septal defects (ASDs) using fast cine magnetic resonance imaging (MRI) and ultrafast three-dimensional magnetic resonance angiography (MRA). BACKGROUND Precise anatomic definition of anomalous pulmonary and systemic veins, and the atrial septum are prerequisites for surgical...

متن کامل

A qualitative and quantitative assessment of cardiac cine Phase contrast MRI: comparison of image quality between 2D and 3D acquisition

Background 3D and gapless multi-slice 2D cine Phase contrast (PC) MRI enables the visualization and analysis of 4D (3D + time) intracardiac flow. However, the image quality which affects the accuracy of segmentation of left ventricle (LV) has not been discussed. In this study, we compared the magnitude image and the source image of PC MR angiography (MagSUM) derived from both 2D and 3D PC MRI. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 7 2  شماره 

صفحات  -

تاریخ انتشار 2005