Italian national survey of blood donors: external quality assessment (EQA) of syphilis testing.

نویسندگان

  • Francesca Vulcano
  • Luisa Milazzo
  • Sabrina Volpi
  • Mara Maria Battista
  • Alessandra Barca
  • Hamisa Jane Hassan
  • Fulvia Pimpinelli
  • Adele Giampaolo
چکیده

The detection of syphilis among blood donors may reveal high-risk sexual behavior, which can go unreported at the time of donor selection and compromise the safety of the donated blood. In Italy, blood is collected, tested, and distributed by transfusion services (TSs), which also perform outpatient transfusions. Although the TSs must screen for syphilis by law, there are no indications of the specific type of method to be used, generating discrepancies in the results obtained by the different TSs. To determine the proficiency of the TSs in screening for syphilis, we performed an external quality assessment (EQA). The EQA was based on two shipments of serum panels; 133 and 118 of the 326 existing TSs participated in the first and second shipments, respectively. Each panel consisted of both positive and negative serum samples. The results confirmed that the use of a single nontreponemal test (the Venereal Disease Research Laboratory [VDRL] and the rapid plasma reagin [RPR] tests) is the least sensitive means of identifying samples that are positive for syphilis antibodies. We also found that the interpretation of the results of manual techniques, such as the RPR test, the VDRL test, the Treponema pallidum hemagglutination (TPHA) assay, and the T. pallidum particle agglutination (TPPA) assay, can vary greatly among different TSs and operators. Total Ig enzyme immunoassays (EIAs) are the most sensitive. However, the determination of syphilis on the basis of the results of a single test is not sufficient for an accurate screening; and all blood units should thus be assessed by two distinct treponemal tests, that is, a total Ig EIA and the TPHA or the TPPA assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The implementation of an external quality assurance method for point- of- care tests for HIV and syphilis in Tanzania

BACKGROUND External quality assurance (EQA) programmes, which are routinely used in laboratories, have not been widely implemented for point-of- care tests (POCTs). A study was performed in ten health centres in Tanzania, to implement the use of dried blood spots (DBS) as an EQA method for HIV and syphilis (POCTs). METHOD DBS samples were collected for retesting at a reference laboratory and ...

متن کامل

Rethinking about continuous quality assessment in Iran higher education: Need for strengthening national evaluation agencies and framework revision

Success of national institutions of quality assessment (NIQA) and accreditation of quality depends on the external quality assurance (EQA) processes. In spite of the fact, it is more than two decades that continuous quality assessment started in higher education in Iran. Nevertheless, the external in higher education quality assessment (non-medical), has not been done in an organized way yet. A...

متن کامل

Survey of medical genetic services in Italy: year 2011

BACKGROUND The aim of this study was to collect information about 2011 genetic activities in Italy, with the purpose of providing guidance to the national health systems in order to improve genetic services. METHODS A web-based survey was carried out to achieve the information. RESULTS Data were collected from 268 macrostructures hosting 517 services and employing 3246 persons. About 295,00...

متن کامل

[Current status of external quality assessment of syphilis test in Korea].

BACKGROUND Current status of external quality assessment (EQA) of laboratory tests for syphilis in Korea was analyzed to find out the problems that should be improved in the future. METHODS Based on the data from the external quality assessment program performed twice a year by the Immunoserology Subcommittee of the Korean Association of Quality Assurance for Clinical Laboratory from the year...

متن کامل

Results of the National External Quality Assessment for Toxoplasmosis Serological Testing in China

BACKGROUND Toxoplasmosis is typically diagnosed by serologic testing. External quality assessment (EQA) of clinical laboratories could ensure the accuracy and reliability of serological tests. We assessed the quality of toxoplasma serological assays in Chinese clinical laboratories by an EQA performed between 2004 and 2013 by the National Center for Clinical Laboratories. METHODOLOGY AND FIND...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 48 3  شماره 

صفحات  -

تاریخ انتشار 2010