Comparison of an in-pharmacy automated blood pressure kiosk to daytime ambulatory blood pressure in hypertensive subjects.
نویسندگان
چکیده
The objective of this study was to compare serial readings from an in-pharmacy automated blood pressure (BP) kiosk to mean daytime ambulatory BP. A total of 100 community-dwelling adults with hypertension underwent (1) three baseline automated office readings; (2) three in-pharmacy readings on each of four visits (12 total) using the PharmaSmart PS-2000 kiosk; and (3) 24-hour ambulatory BP monitoring between in-pharmacy visits two and three. Paired t-tests, Bland-Altman plots, and Pearson correlation coefficients were used for analysis. Mean BPs were 137.8 ± 13.7/81.9 ± 12.2 mm Hg for in-pharmacy and 135.5 ± 11.7/79.7 ± 10.0 mm Hg for daytime ambulatory (difference of 2.3 ± 9.5/2.2 ± 6.9 mm Hg [P ≤ .05]). Bland-Altman plots depicted a high degree of BP variability but did not show clinically important systematic BP differences. With ambulatory BP as the reference standard, in-pharmacy device results were similar to automated office results. The PharmaSmart PS-2000 closely approximated mean daytime ambulatory BP, supporting the use of serial readings from this device in the assessment of BP.
منابع مشابه
Effects of Ramadan fasting on ambulatory blood pressure in hypertensive patients
Background: Previous studies have indicated that Ramadan fasting has beneficial effects on cardiovascular risk factors, specially blood pressure and heart rate. In the present study, the effect of Ramadan fasting on 24-hour ambulatory blood pressure and heart rate has been investigated. Materials and Methods: This prospective observational study was conducted on two groups of individuals. Six p...
متن کاملMeasurement of blood pressure in the office.
Measurement of Blood Pressure in the Office To the Editor: The algorithm for office blood pressure recently proposed by Myers et al1 does not allow for the discernment of isolated clinic or masked hypertension. In a recent study we measured observed automated blood pressure (nurse present), unobserved automated blood pressure (3 readings at 3-minute intervals after 5 minutes of rest), and ambul...
متن کاملBlood pressure response to hyperventilation test reflects daytime pressor profile.
Recent studies show that healthy subjects and patients with moderate hypertension have different pressor responses to hyperventilation, depending on their sympathoadrenergic reactivity. In the present study, we investigated whether a different response to the hyperventilation test is related to differences in the daily blood pressure profiles recorded with noninvasive ambulatory monitoring. For...
متن کاملBody mass index and ambulatory blood pressure monitoring.
Body Mass Index and Ambulatory Blood Pressure Monitoring To the Editor: Kotsis et al evaluated the relationship between body mass index and various ambulatory blood pressure parameters in referred untreated subjects (Hypertension, April 2005 issue).1 They report increased incidence of white-coat hypertension and nondipping pattern among obese subjects. We believe these findings were produced by...
متن کاملComparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement
Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Society of Hypertension : JASH
دوره 9 2 شماره
صفحات -
تاریخ انتشار 2015