Supplemental oxygen impairs detection of hypoventilation by pulse oximetry.

نویسندگان

  • Eugene S Fu
  • John B Downs
  • John W Schweiger
  • Rafael V Miguel
  • Robert A Smith
چکیده

STUDY OBJECTIVE This two-part study was designed to determine the effect of supplemental oxygen on the detection of hypoventilation, evidenced by a decline in oxygen saturation (Spo(2)) with pulse oximetry. DESIGN Phase 1 was a prospective, patient-controlled, clinical trial. Phase 2 was a prospective, randomized, clinical trial. SETTING Phase 1 took place in the operating room. Phase 2 took place in the postanesthesia care unit (PACU). PATIENTS In phase 1, 45 patients underwent abdominal, gynecologic, urologic, and lower-extremity vascular operations. In phase 2, 288 patients were recovering from anesthesia. INTERVENTIONS In phase 1, modeling of deliberate hypoventilation entailed decreasing by 50% the minute ventilation of patients receiving general anesthesia. Patients breathing a fraction of inspired oxygen (Fio(2)) of 0.21 (n = 25) underwent hypoventilation for up to 5 min. Patients with an Fio(2) of 0.25 (n = 10) or 0.30 (n = 10) underwent hypoventilation for 10 min. In phase 2, spontaneously breathing patients were randomized to breathe room air (n = 155) or to receive supplemental oxygen (n = 133) on arrival in the PACU. MEASUREMENTS AND RESULTS In phase 1, end-tidal carbon dioxide and Spo(2) were measured during deliberate hypoventilation. A decrease in Spo(2) occurred only in patients who breathed room air. No decline occurred in patients with Fio(2) levels of 0.25 and 0.30. In phase 2, Spo(2) was recorded every min for up to 40 min in the PACU. Arterial desaturation (Spo(2) < 90%) was fourfold higher in patients who breathed room air than in patients who breathed supplemental oxygen (9.0% vs 2.3%, p = 0.02). CONCLUSION Hypoventilation can be detected reliably by pulse oximetry only when patients breathe room air. In patients with spontaneous ventilation, supplemental oxygen often masked the ability to detect abnormalities in respiratory function in the PACU. Without the need for capnography and arterial blood gas analysis, pulse oximetry is a useful tool to assess ventilatory abnormalities, but only in the absence of supplemental inspired oxygen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy.

BACKGROUND Pulse oximetry is a widely accepted procedure for ventilatory monitoring during gastrointestinal endoscopy, but this method provides an indirect measurement of the respiratory function. In addition, detection of abnormal ventilatory activity can be delayed, especially if supplemental oxygen is provided. Capnography offers continuous real-time measurement of expiratory carbon dioxide....

متن کامل

Transcutaneous carbon dioxide monitoring: literature review.

Dental anxiety is very common, affecting 22% of the population. One way to increase access to dental care is by the use of BDZs in conscious sedation. These drugs are known to be safe when titrated. BDZs work by stimulating GABAA receptors within inhibitory pathways of the CNS. A consequence of this is a reduction in respiratory drive. Thus assessing saturation of peripheral oxygen (SpO2) is ma...

متن کامل

Capnography compared to pulse oximetry for early detection of respiratory compromise in non-intubated patients undergoing gastrointestinal endoscopy procedures: a systematic review protocol.

REVIEW QUESTION/OBJECTIVE Does the use of capnography versus pulse oximetry increase the early detection of respiratory compromise and improve safety in non-intubated patients undergoing moderate sedation for gastrointestinal endoscopy procedures?Respiratory compromise will be detected by alveolar hypoventilation/hyperventilation (EtCO2 < 35 mmHg/EtCO2 > 50 mmHg), arterial oxygen desaturation (...

متن کامل

Resident research and graduate medical education funding.

of 100% oxygen during induction and emergence is standard practice for the vast majority of anesthetists, our study reflects the impact of high intraoperative inspired oxygen in actual practice. The use of 100% oxygen for induction and emergence also likely had minimal effect on our results because the degree of atelectasis induced by administration of 100% oxygen for only a few minutes is rela...

متن کامل

Capnography monitoring in procedural sedation for bronchoscopy.

Moderate sedation/analgesia, formerly known as “conscious sedation,” is commonly used during bronchoscopy for patients’ comfort and safety around the world. This is mostly because, during the procedure, patients may experience pain, excessive cough, and sensation of asphyxiation. These experiences may lead to anxiety, hypertension, and even arrhythmias. Moreover, they may leave behind an unplea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 126 5  شماره 

صفحات  -

تاریخ انتشار 2004