Micro-scale anticonvulsant assay with use of nitrogen/phosphorus detector and on-column methylation compared with a macro-scale procedure involving flame-ionization detection.

نویسندگان

  • C J Least
  • G F Johnson
  • H M Solomon
چکیده

We report a modified micro-scale gas-chromatographic procedure for determining phenobarbital, primidone, and diphenylhydantoin in serum with use of a nitrogen/phosphorus detector. Serum, 20 mul, is extracted into chloroform, the solvent is evaporated, and the residue dissolved in dilute (32 mmol/liter) trimethylanillinium hydroxide, which yields the methyl-derivatives of the drugs upon on-column injection. Within-run precision (CV) for the three drugs was 1.0, 2.1, and 1.4+, respectively, at concentrations of 19.2, 13.2, and 18.9 mg/liter; run-to-run precision at these concentrations was 4.4, 3.8, and 2.8%. Comparison of the 20-mul micro-scale procedure (y) with our conventional, flame-ionization macro-scale procedure (x), in which on-column methylation is used and which requires 1 ml of serum, gave the following respective results: y = 1.01 X -- 0.16 mg/liter, r = 0.992, y = 1.02 X + 0.29 mg/liter, r = 0.973; and y = 0.96x + 0.04 mg/liter, r = 0.996.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gas-chromatographic micro-scale procedure for theophylline, with use of a nitrogen-sensitive detector.

We report a micro-scale procedure for determination of theophylline by use of gas chromatography with nitrogen-sensitive detection. The procedure requires only 10 mul of serum, plasma, or saliva. This sample size makes the determination especially appropriate for monitoring in a pediatric population. With the sample volume used, background interference is equivalent to about 0.1 mg/liter and 0....

متن کامل

Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Performance of a pilot scale biomass gasification and producer gas combustion system using feedstock with controlled nitrogen content

This study is focused on the effects of nitrogen content in biomass feedstock on the producer gas composition and the flue gas NOx emissions from a pilot-scale gasification and combustion system. Biomass gasification has the potential to produce carbon negative energy by using renewable resources. The greenhouse gases emitted by burning fossil fuels have to be reduced, and biomass gasification ...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 3  شماره 

صفحات  -

تاریخ انتشار 1977