A Comparison of Static Occlusion Setting Methods : Fluid Drop Rate and Pressure Drop

نویسنده

  • Thomas Rath
چکیده

Tubing circuits primed with water were constructed on two roller pumps to characterize and compare two static methods of setting the occlusion on roller pumps (fluid drop rate and pressure drop rate). Twelve separate experiments were performed in which PVC boot tubing diameters (1/2 in, 3/8 in and 1/4 in), roller position (each roller alone on a two roller pump) and roller occlusion (total occlusion to 0.004 in underocclusion) were varied. Fluid drop rates were measured from two heights (30 in and 1 m) above the pump head where drops of 1 em and 1 in were timed for each occlusion setting. Pressure drop was measured by clamping the outlet tubing, injecting fluid into the tubing between the clamp and roller elevating the pressure to 300 mmHg and observing the rate that it dropped at each occlusion setting. Fluid drop rate and pressure drop rate were positively correlated at all occlusion settings and tubing sizes (p < 0.001). Using a single roller occlusion and an optimal fluid drop rate of .5 to 1.5 em/min. at 30 in height, pressure drops (mmHg/min.) were (mean± SD); 1/2 in tubing= 263 ± 33, 3/8 in= 241 ±52, 1/4 in= 264 ± 11. For a fluid drop rate of 1.27 to 3.81 em/min. at 1 m height, pressure drops were (mean± SD); 1/2 in= 266 ± 33, 3/8 in=278 ± 17, 114 in=274 ± 20. The occlusion settings or occlusion gap varied significantly (p < 0.001) between pumps and tubing sets. Thus, it appears as though pressure drop rate can predict fluid drop rate at just nonocclusive pump settings; however, the occlusion should be rechecked every time a different pump or boot tubing is used. Volume 28, Number 1, March 1996 Address correspondence to : Thomas Rath, BS c/o Robin Sutton, MS, CCP Department of Surgery 1601 JCP University of Iowa Hospitals and Clinics Iowa City, lA 52242

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Influence of the Pipe’s Material and the Mass Flow Rate on the Pressure Drop and Velocity Variation During Pneumatic Conveying of Wheat Using Computational Fluid Dynamics

According to flexibility of pneumatic conveying systems with respect to other types of transmission systems, this system has wide application in industry and agriculture processes. One important application of this system is in the loading and unloading tankers and powdery bulk materials such as trucks carrying cement, plaster and sand. Conveying efficiency is associated with pressure, which in...

متن کامل

The Influence of the Pipe’s Material and the Mass Flow Rate on the Pressure Drop and Velocity Variation During Pneumatic Conveying of Wheat Using Computational Fluid Dynamics

According to flexibility of pneumatic conveying systems with respect to other types of transmission systems, this system has wide application in industry and agriculture processes. One important application of this system is in the loading and unloading tankers and powdery bulk materials such as trucks carrying cement, plaster and sand. Conveying efficiency is associated with pressure, which in...

متن کامل

Influence of Pipeline Operating Pressure on Value Setting of Automatic Control Valves at Different Pressure Drop Rates

When a natural gas pipeline ruptures, the adjacent upstream and downstream automatic control valves (ACV) should close quickly to prevent leakage or explosion. The differential pressure set point (DPS) at each valve location is the main criteria for value setting in ACV actions. If the DPS is not properly adjusted, the ACV may mistakenly close or it may not take any actions at a proper ti...

متن کامل

Effect of baffle oientation on shell tube heat exchanger performance

In this paper, fluid flow and heat transfer in the laboratory (small size) shell tube heat exchanger are analysed by computational fluid dynamic software. In this type of shell tube heat exchanger baffles with different angles of rotation: 00 (horizontal segmental baffle), 150 (from horizontal), 300, 450, 600, 750, 900 (vertical segmental baffle) is used. Effect of baffle orientation on shell t...

متن کامل

Experimental investigation on heat transfer and pressure drop of Al2O3-base oil nanofluid in a helically coiled tube and effect of turbulator on the thermal performance of shell and tube heat exchanger

These days With respect to the high importance of energy concept, limitation of natural resources, regulation of environmental issues, and global warming, heat transfer systemschr(chr('39')39chr('39')) applications get more attention. In the present paper, the experimental effect of Nano-fluid and turbulator on the heat transfer and pressure drop is investigated. AL2O3-SN300 base oil as nanoflu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997