Frequency-Selective Fat Suppression Radiofrequency Pulse Train to Remove Olefinic Fats
نویسنده
چکیده
CHESS pulse can suppress the signal originating from aliphatic fat protons but cannot suppress the signal from olefinic fat protons, which is near the resonance frequency of water protons. Adipose tissue contains various fat species; aliphatic fat comprises about 90 % and olefinic fat about 10 % of adipose tissue. Thus, CHESS pulse cannot be used to suppress the signal from adipose tissue completely. The purpose of this study was to find a method to suppress the signal from adipose tissue completely. The Fatsat train pulse, created with an arbitrary flip angle and insensitive to B1 inhomogeneity, was used. Because B1 inhomogeneity is larger on higher field magnetic resonance imaging, the fat suppression radiofrequency pulse needs to be B1-insensitive. To investigate a percentage of olefinic fat in adipose tissues, the excitation frequency of the Fatsat train pulse was varied from -240 to +400 Hz and the images and fat-suppressed images were obtained. The presence of olefinic fat comprising about 10 % of abdominal adipose tissue was identified. The result agreed with some previous papers. Complete fat suppression could be achieved by partial (10 %) inversion of longitudinal aliphatic fat magnetization and by canceling out the two fat magnetizations. The flip angle was identified to about 95°. In conclusion, the cause that the signal from adipose tissues cannot be suppressed completely has been found. Improved images that signals from adipose tissues were suppressed completely have been demonstrated. This technique can also be applied to several pulse sequences.
منابع مشابه
The Application of Fat-Suppression MR Pulse Sequence in the Diagnosis of Bone-Joint Disease
Fat-suppression technology of magnetic resonance is very important in clinical practice. This article is written to interpret the principle, advantages/disadvantages and clinical applications of some regular fat-suppression sequences in the diagnosis of Bone-Joint Disease, including: 1) frequency-selective saturation (FS); 2) short-TI inversion recovery (STIR); 3) frequency selective inversion ...
متن کاملFour dimensional spectral-spatial fat saturation pulse design.
PURPOSE The conventional spectrally selective fat saturation pulse may perform poorly with inhomogeneous amplitude of static (polarizing) field (B0 ) and/or amplitude of (excitation) radiofrequency field (B1 ) fields. We propose a four dimensional spectral-spatial fat saturation pulse that is more robust to B0/B1 inhomogeneity and also shorter than the conventional fat saturation pulse. THEOR...
متن کاملA simple low-SAR technique for chemical-shift selection with high-field spin-echo imaging.
We have discovered a simple and highly robust method for removal of chemical shift artifact in spin-echo MR images, which simultaneously decreases the radiofrequency power deposition (specific absorption rate). The method is demonstrated in spin-echo echo-planar imaging brain images acquired at 7 T, with complete suppression of scalp fat signal. When excitation and refocusing pulses are suffici...
متن کاملFat signal suppression in head and neck imaging using fast spin-echo-IDEAL technique.
We present our initial experience with the use of a modified 3-point Dixon technique to obtain reliable fast spin-echo T1- and T2-weighted fat-suppressed images in the soft-tissue neck. The method has less sensitivity to magnetic field inhomogeneity than frequency-selective radiofrequency fat saturation and provides uniform fat suppression even near tissue-tissue and air-tissue interfaces. Clin...
متن کاملThe Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 44 شماره
صفحات -
تاریخ انتشار 2013