Model to Estimate Threshold Mechanical Stability of Lower Lateral Cartilage.

نویسندگان

  • James Hakjune Kim
  • Ashley Hamamoto
  • Nicole Kiyohara
  • Brian J F Wong
چکیده

IMPORTANCE In rhinoplasty, techniques used to alter the shape of the nasal tip often compromise the structural stability of the cartilage framework in the nose. Determining the minimum threshold level of cartilage stiffness required to maintain long-term structural stability is a critical aspect in performing these surgical maneuvers. OBJECTIVE To quantify the minimum threshold mechanical stability (elastic modulus) of lower lateral cartilage (LLC) according to expert opinion. METHODS Five anatomically correct LLC phantoms were made from urethane via a 3-dimensional computer modeling and injection molding process. All 5 had identical geometry but varied in stiffness along the intermediate crural region (0.63-30.6 MPa). DESIGN, SETTING, AND PARTICIPANTS A focus group of experienced rhinoplasty surgeons (n = 33) was surveyed at a regional professional meeting on October 25, 2013. Each survey participant was presented the 5 phantoms in a random order and asked to arrange the phantoms in order of increasing stiffness based on their sense of touch. Then, they were asked to select a single phantom out of the set that they believed to have the minimum acceptable mechanical stability for LLC to maintain proper form and function. MAIN OUTCOMES AND MEASURES A binary logistic regression was performed to calculate the probability of mechanical acceptability as a function of the elastic modulus of the LLC based on survey data. A Hosmer-Lemeshow test was performed to measure the goodness of fit between the logistic regression and survey data. The minimum threshold mechanical stability for LLC was taken at a 50% acceptability rating. RESULTS Phantom 4 was selected most frequently by the participants as having the minimum acceptable stiffness for LLC intermediate care. The minimum threshold mechanical stability for LLC was determined to be 3.65 MPa. The Hosmer-Lemeshow test revealed good fit between the logistic regression and survey data (χ23 = 0.92, P = .82). CONCLUSIONS AND RELEVANCE This study presents a novel method of modeling anatomical structures and quantifying the mechanical properties of nasal cartilage. Quantifying these parameters is an important step in guiding surgical maneuvers performed in rhinoplasty. LEVEL OF EVIDENCE 5.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Model for estimating the threshold mechanical stability of structural cartilage grafts used in rhinoplasty.

OBJECTIVES/HYPOTHESIS Characterizing the mechanical properties of structural cartilage grafts used in rhinoplasty is valuable because softer engineered tissues are more time- and cost-efficient to manufacture. The aim of this study is to quantitatively identify the threshold mechanical stability (e.g., Young's modulus) of columellar, L-strut, and alar cartilage replacement grafts. STUDY DESIG...

متن کامل

Mechanical analysis of the effects of cephalic trim on lower lateral cartilage stability.

OBJECTIVE To determine how mechanical stability changes in the lower lateral cartilage (LLC) after varying degrees of cephalic resection in a porcine cartilage nasal tip model. METHODS Alar cartilage was harvested from fresh porcine crania (n = 14) and sectioned to precisely emulate a human LLC in size and dimension. Flexural mechanical analysis was performed both before and after cephalic tr...

متن کامل

New Approach to Instability Threshold of a Simply Supported Rayleigh Shaft

The main goal of this research is to analyse the effect of angular velocity on stability and vibration of a simply supported Rayleigh rotating shaft. To this end, non-dimensional kinetic and potential energies are written while lateral vibration is considered. Finite element method is employed to discrete the formulations and Linear method is applied to analyse instability threshold of a rotati...

متن کامل

Analysis of Roll Control System to Eliminate Liquid Sloshing Effect on Lateral Stability of an Articulated Vehicle Carrying Liquid

In this paper, the consequences of filled volume on the transient lateral dynamic and stabilities boundaries displacement of an articulated vehicle carrying liquid is investigated. First, a sixteen-degrees-of-freedom nonlinear dynamic model of an articulated vehicle is developed then, using TruckSim software the model is validated. Next, the dynamic interaction of the fluid cargo with the vehic...

متن کامل

Liquid Sloshing Effect Analysis on Lateral Dynamics of an Articulated Vehicle Carrying Liquid for Various Filled Volumes

In this paper, the consequences of filled volume on the transient lateral dynamic and stabilities boundaries displacement of an articulated vehicle carrying liquid is investigated. First, a sixteen-degrees-of-freedom nonlinear dynamic model of an articulated vehicle is developed. Then, the model is validated by using TruckSim software. Next, the dynamic interaction of the fluid cargo with the v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • JAMA facial plastic surgery

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2015