Wear of enamel opposing zirconia and lithium disilicate after adjustment, polishing and glazing.

نویسندگان

  • Nathaniel C Lawson
  • Sridhar Janyavula
  • Sarah Syklawer
  • Edward A McLaren
  • John O Burgess
چکیده

OBJECTIVES To compare the wear and opposing enamel wear of adjusted (A); adjusted and polished (AP); and adjusted and glazed (AG) zirconia and lithium disilicate. METHODS Specimens (n=8) were prepared of lithium disilicate (A, AP, and AG), zirconia (A, AP, and AG), veneering porcelain, and enamel (control). Surface roughness was measured for each ceramic. In vitro wear was conducted in the UAB-chewing simulator (10 N vertical load/2mm slide/20 cycles/min) with lubricant (33% glycerin) for 400,000 cycles. Isolated cusps of extracted molars were used as antagonists. Scans of the cusps and ceramics were taken at baseline and 400,000 cycles with a non-contact profilometer and super-imposed to determine wear. Data were analyzed with ANOVA and Tukey-Kramer post hoc tests (alpha=0.05). RESULTS A and AP zirconia showed no detectable signs of wear, and the veneering porcelain demonstrated the most wear. All other ceramics showed significantly less volumetric loss than the veneering porcelain, comparable to enamel-enamel wear. Veneering porcelain produced the most opposing enamel wear (2.15 ± 0.58 mm(3)). AP lithium disilicate and zirconia showed the least amount of enamel wear (0.36 ± 0.09 mm(3) and 0.33 ± 0.11 mm(3) respectively). AG lithium disilicate had statistically similar enamel wear as AP lithium disilicate, but A lithium disilicate had more enamel wear. A and AG zirconia had more enamel wear than AP zirconia. No statistically significant difference was seen between the enamel-enamel group and any other group except the veneering porcelain. CONCLUSIONS Zirconia has less wear than lithium disilicate. Wear of enamel opposing adjusted lithium disilicate and zirconia decreased following polishing. CLINICAL SIGNIFICANCE Zirconia experiences less and lithium disilicate experiences equivalent occlusal wear as natural enamel. It is preferable to polish zirconia and lithium disilicate after adjustment to make them wear compatible with enamel. Veneering of zirconia and lithium disilicate should be avoided in areas of occlusal contact to prevent enamel wear.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear performance of monolithic dental ceramics with different surface treatments.

OBJECTIVE To investigate the two-body wear performance of monolithic dental ceramics with different surface treatments. METHOD AND MATERIALS Standardized specimens (n = 8/ series) were fabricated from three monolithic dental ceramics (experimental translucent zirconia, experimental shaded zirconia, lithium disilicate). Four groups of each material were defined according to clinically relevant...

متن کامل

A study on the wear of enamel caused by monolithic zirconia and the subsequent phase transformation compared to two other ceramic systems

PURPOSE The purpose of this in vitro research project was to evaluate and compare the wear behavior of human tooth enamel opposing monolithic zirconia and other different ceramic restorative materials and also to observe the tetragonal to monoclinic phase transformation in zirconia-based ceramics that may occur while simulating wear occurring at room temperature in a wet environment. MATERIAL...

متن کامل

Effect of Accelerated Aging on Color Stability of Two Silica-Based Ceramics with Leucite and Lithium-Disilicate Crystalline Phases After Glazing and Polishing

Background and Aim: Color match between prosthetic restorations and natural teeth is challenging in dentistry. The aim of the current study was to assess the effect of accelerated aging on color stability of two silica-based ceramics with leucite and lithium disilicate crystalline phases after glazing and polishing surface treatments. Materials and Methods: In this experimental study, 30 disc-...

متن کامل

The Effect of Polishing and Glazing Procedure on Streptococcus Mutans Adhesion of Three CAD/CAM Ceramics (in vitro)

Abstract Background and Aim: Polish and glaze are 2 methods to decrease roughness and bacterial adhesion to the ceramic surfaces. This in vitro study assessed the effect of polish and glaze on the bacterial adhesion of 3 ceramics. Materials and Methods: In this in vitro trial, samples of zirconia-reinforced lithium silicate, lithium disilicate and monolithic zirconia ceramic specimens were mill...

متن کامل

Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns

PURPOSE This study was conducted to evaluate the effects of full-coverage all-ceramic zirconia, lithium disilicate glass-ceramic, leucite glass-ceramic, or stainless steel crowns on antagonistic primary tooth wear. MATERIALS AND METHODS There were four study groups: the stainless steel (Steel) group, the leucite glass-ceramic (Leucite) group, the lithium disilicate glass-ceramic (Lithium) gro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of dentistry

دوره 42 12  شماره 

صفحات  -

تاریخ انتشار 2014