Optical Coherence Tomography, Scanning Laser Polarimetry and Confocal Scanning Laser Ophthalmoscopy in Retinal Nerve Fiber Layer Measurements of Glaucoma Patients

نویسندگان

  • Farsad Fanihagh
  • Stephan Kremmer
  • Gerasimos Anastassiou
  • Maurice Schallenberg
چکیده

PURPOSE To determine the correlations and strength of association between different imaging systems in analyzing the retinal nerve fiber layer (RNFL) of glaucoma patients: optical coherence tomography (OCT), scanning laser polarimetry (SLP) and confocal scanning laser ophthalmoscopy (CSLO). MATERIALS AND METHODOLOGY 114 eyes of patients with moderate open angle glaucoma underwent spectral domain OCT (Topcon SD-OCT 2000 and Zeiss Cirrus HD-OCT), SLP (GDx VCC and GDx Pro) and CSLO (Heidelberg Retina Tomograph, HRT 3). Correlation coefficients were calculated between the structural parameters yielded by these examinations. The quantitative relationship between the measured RNFL thickness globally and for the four regions (superior, inferior, nasal, temporal) were evaluated with different regression models for all used imaging systems. RESULTS The strongest correlation of RNFL measurements was found between devices using the same technology like GDx VCC and GDx Pro as well as Topcon OCT and Cirrus OCT. In glaucoma patients, the strongest associations (R²) were found between RNFL measurements of the two optical coherence tomography devices Topcon OCT and Cirrus OCT (R² = 0.513) and between GDx VCC and GDx Pro (R² = 0.451). The results of the OCTs and GDX Pro also had a strong quantitative relationship (Topcon OCT R² = 0.339 and Cirrus OCT R² = 0.347). GDx VCC and the OCTs showed a mild to moderate association (Topcon OCT R² = 0.207 and Cirrus OCT R² = 0.258). The confocal scanning laser ophthalmoscopy (HRT 3) had the lowest association to all other devices (Topcon OCT R² = 0.254, Cirrus OCT R² = 0.158, GDx Pro R² = 0.086 and GDx VCC R² = 0.1). CONCLUSION The measurements of the RNFL in glaucoma patients reveal a high correlation of OCT and GDx devices because OCTs can measure all major retinal layers and SLP can detect nerve fibers allowing a comparison between the results of this devices. However, CSLO by means of HRT topography can only measure height values of the retinal surface but it cannot distinguish between different retinal layers. This may explain the rather poor correlations and associations between CSLO measurements and those of all other imaging devices which makes it difficult to compare HRT 3 nerve fiber data. These correlations are important in clinical routine especially when different techniques are used in the follow-up of glaucoma patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Structural Glaucoma Progression

PURPOSE To provide an update on the role of optic nerve head and peripapillary retinal nerve fiber layer imaging in monitoring glaucoma progression. METHODS Review of literature. RESULTS Imaging technologies, such as optical coherence tomography, scanning laser polarimetry, and confocal scanning laser ophthalmoscopy, objectively and quantitatively measure the structural change associated wi...

متن کامل

Assessment of the retinal nerve fiber layer in clinical trials of glaucoma neuroprotection.

Assessment of the retinal nerve fiber layer (RNFL) is appealing for use in clinical trials of glaucoma neuroprotection, as it is directly correlated with loss of ganglion cells, which is assumed to be a primary event in glaucomatous damage. Qualitative assessment of the RNFL includes ophthalmoscopy, color stereophotography, and red-free monochromatic photography. In contrast, confocal scanning ...

متن کامل

Comparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma

BACKGROUND We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. MATERIAL/METHODS Study subjects had advanced primary open-angle glaucoma, pre...

متن کامل

Detecting optic nerve head deformation and retinal nerve fiber layer thinning in glaucoma progression

The application of digital imaging technologies including confocal scanning laser ophthalmoscopy (CSLO), optical coherence tomography (OCT), and scanning laser polarimetry (SLP) has significantly improved the detection of optic nerve head (ONH) deformation and progressive retinal nerve fiber layer (RNFL) thinning for assessment of glaucoma progression. Algorithms for change analysis such as top...

متن کامل

Evaluating the optic nerve and retinal nerve fibre layer: the roles of Heidelberg retina tomography, scanning laser polarimetry and optical coherence tomography.

INTRODUCTION For many years, ophthalmologists have looked at the optic nerve head to evaluate the status of glaucoma. Clinical examination of the optic nerve head and retinal nerve fibre layer (RNFL) is however, subjective and sometimes variable. Recent developments in computer-based imaging technologies have provided a means of obtaining quantitative measurements of the optic nerve head topogr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015