Patient specific methods for room‐mounted x‐ray imagers for monoscopic/stereoscopic prostate motion monitoring
نویسندگان
چکیده
PURPOSE To investigate the improvement of combined monoscopic/stereoscopic prostate motion monitoring with room-mounted dual x-ray systems by adopting patient specific methods. METHODS The linac couch was used as a motion stage to simulate 40 highly dynamic real patient prostate trajectories. For each trajectory, 40 s pretreatment and 120 s treatment periods were extracted to represent a typical treatment fraction. Motion was monitored via continuous stereoscopic x-ray imaging of a single gold fiducial and images were retrospectively divided into periods of stereoscopic and monoscopic imaging to simulate periodic blocking of the room-mounted system by the gantry during arc-based therapy. The accuracy of the combined motion monitoring was assessed by comparison with the linac couch log files. To estimate 3-D marker position during monoscopic imaging, the use of population statistics was compared to both maximum likelihood estimation and stereoscopic localization based estimation of individualized prostate probability density functions (PDFs) from the pretreatment period. The inclusion of intrafraction updating was compared to pretreatment initialization alone. RESULTS Combined mono/stereoscopic localization was successfully implemented. During the transitions from stereoscopic to monoscopic imaging, fiducial localization exhibits sharp discontinuities when population PDFs were employed. Patient specific PDFs successfully reduced the localization error when estimated from stereoscopic localizations, whereas maximum likelihood estimation (MLE) was too unstable in the room-mounted geometry. Intrafraction stereoscopic updating provided further increases in accuracy. Residual error tended to decrease throughout the treatment fraction, as the patient-specific PDFs became more refined. CONCLUSIONS This is the first demonstration of toggled monoscopic/stereoscopic localization using room-mounted dual x-ray imagers, enabling continuous intrafraction motion monitoring for these systems. We showed that both pretreatment individualization and intrafraction updating should be used to provide the most accurate motion monitoring.
منابع مشابه
Stereoscopic vs. monoscopic detection of masses on breast tomosynthesis projection images
The goal of this study was to assess if stereoscopic viewing of breast tomosynthesis projection images impacted mass detection performance when compared to monoscopic viewing. The dataset for this study, provided by Hologic, Inc., contained 47 craniocaudal cases (23 biopsy proven malignant masses and 24 normals). Two projection images that were separated by 8 degrees were chosen to form a stere...
متن کاملStereoscopic panoramic video generation using centro-circular projection technique
This paper presents a method of stereoscopic panoramic video generation including techniques for panorama projection, stitching and calibration for various depth planes. The methods described can be used on video sequences captured by an arrangement of multiple pairs of cameras or multiple stereoscopic cameras mounted on a regular polygonal shaped camera rig. Algorithms can also be used in comb...
متن کاملPhotogrammetric methods applied to Svalbard glaciers: accuracies and challenges
Use of digital images is expanding as a tool for glacier monitoring, and smallformat time-lapse cameras are increasingly being used for glacier monitoring of fast-flowing glaciers. Stereoscopic imagery is preferable since it yields direct displacement results but stereo photogrammetry has more requirements regarding geometry in set-up and control points, as well as the additional cost of anothe...
متن کاملIntegrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors.
The design of an integrated radiotherapy imaging system (IRIS), consisting of gantry mounted diagnostic (kV) x-ray tubes and fast read-out flat-panel amorphous-silicon detectors, has been studied. The system is meant to be capable of three main functions: radiographs for three-dimensional (3D) patient set-up, cone-beam CT and real-time tumour/marker tracking. The goal of the current study is to...
متن کاملDigital imaging of the optic nerve head: monoscopic and stereoscopic analysis.
AIMS To compare monoscopic and stereoscopic assessment of the optic disc using novel software for the digital stereoscopic analysis of optic disc stereopairs. METHODS Software was developed for the stereoscopic display of digital optic disc images using an interlaced display method. Neuroretinal rim width was determined at 10 degree intervals around the optic disc using a custom (stereoscopic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -
تاریخ انتشار 2017