Femtosecond infrared intrastromal ablation and backscattering-mode adaptive-optics multiphoton microscopy in chicken corneas

نویسندگان

  • Emilio J. Gualda
  • Javier R. Vázquez de Aldana
  • M. Carmen Martínez-García
  • Pablo Moreno
  • Juan Hernández-Toro
  • Luis Roso
  • Pablo Artal
  • Juan M. Bueno
چکیده

The performance of femtosecond (fs) laser intrastromal ablation was evaluated with backscattering-mode adaptive-optics multiphoton microscopy in ex vivo chicken corneas. The pulse energy of the fs source used for ablation was set to generate two different ablation patterns within the corneal stroma at a certain depth. Intrastromal patterns were imaged with a custom adaptive-optics multiphoton microscope to determine the accuracy of the procedure and verify the outcomes. This study demonstrates the potential of using fs pulses as surgical and monitoring techniques to systematically investigate intratissue ablation. Further refinement of the experimental system by combining both functions into a single fs laser system would be the basis to establish new techniques capable of monitoring corneal surgery without labeling in real-time. Since the backscattering configuration has also been optimized, future in vivo implementations would also be of interest in clinical environments involving corneal ablation procedures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Second-harmonic generation microscopy of photocurable polymer intrastromal implants in ex-vivo corneas.

A custom adaptive-optics (AO) multiphoton microscope was used to visualize the corneal stroma after the insertion of a photocurable polymer material. A lamellar pocket was created and a certain amount of polymer in liquid form was injected. This turned into a rigid film after UV irradiation. Intact eyes were used as control. Tomographic and regular second harmonic generation (SHG) microscopy im...

متن کامل

A mouse model of lamellar intrastromal femtosecond laser keratotomy: ultra-structural, inflammatory, and wound healing responses

PURPOSE The availability of knockout mouse species provide a highly versatile platform for critically examining the corneal wound healing response. We aimed to develop and characterize the wound healing response in a mouse model of intrastromal femtosecond laser (FSL) keratotomy. METHODS An intrastromal lamellar dissection using a Visumax FSL was performed on 16 wild type mice (C57BL6) . The ...

متن کامل

Adaptive optics in multiphoton microscopy: comparison of two, three and four photon fluorescence.

We demonstrate adaptive optics system based on nonlinear feedback from 3- and 4-photon fluorescence. The system is based on femtosecond pulses created by soliton self-frequency shift of a 1550-nm fiber-based femtosecond laser together with micro-electro-mechanical system (MEMS) phase spatial light modulator (SLM). We perturb the 1020-segment SLM using an orthogonal Walsh sequence basis set with...

متن کامل

Morphologic and histopathologic changes in the rabbit cornea produced by femtosecond laser-assisted multilayer intrastromal ablation.

PURPOSE To observe morphologic and histopathologic changes in the midperiphery of the rabbit cornea produced by femtosecond laser-assisted multilayer intrastromal ablation, determine whether this method may be used to correct myopia, and study how the cornea heals when the epithelium is not injured. METHODS The right eyes of 10 New Zealand White rabbits were used for the experiments. A 60-kHz...

متن کامل

Efficient multiphoton-absorption-induced luminescence in single-crystalline ZnO at room temperature.

At room temperature, multiphoton absorption- (MPA-) induced photoluminescence in ZnO strongly driven by a femtosecond (fs) near-infrared laser is studied. Two-photon absorption and three-photon absorption are proved to be responsible for the intense luminescence, when the wavelength of the fs excitation laser is above and below the half-bandgap of ZnO, respectively. Strong MPA absorption in ZnO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2011