The Biological Safety of Stainless Steel Needles Used in Warm-needling
نویسندگان
چکیده
Warm-needling (also called thermo-acupuncture) is a combination of acupuncture and moxibustion. Due to the intense heat involved, there have been concerns over the biological safety of the acuneedles used in the treatment. This paper reports two phases of a safety test. For a preliminary test, we compared the temperature change patterns of stainless steel (SS304) needles and traditional gold alloy needles, which have been increasingly replaced by the former. To verify the effects of the presence of coating materials, the main test involved three different kinds of SS304: silicone-coated, salicylic acid-coated and non-coated needles. Each group of needles was tested for pH level, heavy metals and UV absorbance spectrum along with biological tests on the cytotoxicity and hemolysis of the needle. All the tests on the extractants from the needles were negative. In the biological tests, each test result showed a significant difference from the positive control samples, while no significant difference was observed compared with the negative control samples. In the hemolysis tests, all samples satisfied the Korean Government Standards. All the results suggest that SS304 needles are biologically safe to be used in warm-needling, though they can be improved to perform as well as the gold alloy needles in terms of temperature fluctuations.
منابع مشابه
Examination of surface conditions and other physical properties of commonly used stainless steel acupuncture needles
OBJECTIVES The present work examined the surface conditions and various other physical properties of sterilised single-use stainless steel acupuncture needles from two of the most popular brands widely used in many countries. METHODS Scanning electron microscope (SEM) images were taken for 10 randomly chosen needles from each brand. Further SEM images were taken after each of these needles un...
متن کاملStrain Evolution in Cold-Warm Forged Steel Components Studied by Means of EBSD Technique
Electron BackScatter Diffraction (EBSD) in conjunction with Field-Emission Environmental Scanning Electron Microscopy (FEG-ESEM) has been used to evaluate the microstructural and local plastic strain evolution in different alloys (AISI 1005, AISI 304L and Duplex 2205) deformed by a single-stage cold and warm forging process. The present work is aimed to describe the different behavior of the au...
متن کاملElectrochemical corrosion of STS304 acupuncture needles by electrical stimulation.
We present the first investigation of electrical corrosion in acupuncture needles after electrical stimulation. Using scanning electron microscopy, we observed the occurrence of electrochemical corrosion on the surface of stainless steel 304 acupuncture needles after electrical stimulation in the tibial muscles of rats. Biphasic pulse electrical stimuli with 10-Hz frequency, 1-mA intensity and ...
متن کاملDry Needling Is One Type of Acupuncture
Background: Acupuncture has been practiced in Western countries for more than 40 years. One type of needling therapy termed dry needling has gained popularity rapidly since 2000. However a strong debate and conflict exists between proponents of dry needling by physical therapists and proponents of acupuncture. Objectives: This review explores similarities and differences between dry needling an...
متن کاملDiamond knife in cataract surgery.
SURGEONS have always searched for sharper cutting instruments whether it be needles, scissors, or knives. The stainless steel blade has until recently been the sharpest knifeedge, but diamond knives$ are much sharper. The diamonds are of gem quality and the blades were developed originally for sectioning biological materials especially for electron microscopy. This paper presents their use in m...