High Acceleration 3D Compressed Sensing Hyperpolarized C MRSI of a Transgenic Mouse Model of Liver Cancer
نویسندگان
چکیده
S. Hu, A. Balakrishnan, M. Lustig, P. E. Larson, R. Bok, J. Kurhanewicz, S. J. Nelson, J. M. Pauly, A. Goga, and D. B. Vigneron Dept. of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States, UCSF & UCB Joint Graduate Group in Bioengineering, San Francisco, CA, United States, Dept. of Medicine, Division of Hematology/Oncology, University of California, San Francisco, CA, United States, Dept. of Electrical Engineering, Stanford University, Stanford, CA, United States
منابع مشابه
Compressed sensing for resolution enhancement of hyperpolarized 13C flyback 3D-MRSI.
High polarization of nuclear spins in liquid state through dynamic nuclear polarization has enabled the direct monitoring of 13C metabolites in vivo at very high signal-to-noise, allowing for rapid assessment of tissue metabolism. The abundant SNR afforded by this hyperpolarization technique makes high-resolution 13C 3D-MRSI feasible. However, the number of phase encodes that can be fit into th...
متن کاملImproved Temporal Resolution for Hyperpolarized C 3D Dynamic MRSI with Compressed Sensing
Introduction: Time-resolved spectroscopic imaging following injection of hyperpolarized [1-C]-pyruvate can provide valuable and detailed metabolic information, including perfusion, uptake and kinetics. We introduced a dynamic C 3D MRSI method that combined multiband excitation pulses with a compressed sensing (CS) acquisition and reconstruction scheme [1]. In this project, we have reduced the m...
متن کاملHyperpolarized [2-C] Fructose: A hemiketal substrate for in vivo metabolic imaging
INTRODUCTION: Hyperpolarized C labeled molecular probes have shown the potential to investigate important metabolic pathways and other physiologic parameters, such as pH, in in vivo pre-clinical models of cancer. Carboxylate carbons have been the primary targets for development of hyperpolarized C labeled molecular probes due to their relatively long T1 relaxation times. However, there are a nu...
متن کاملHyperpolarized C-13 spectroscopic imaging of the TRAMP mouse at 3T-initial experience.
The transgenic adenocarcinoma of mouse prostate (TRAMP) mouse is a well-studied murine model of prostate cancer with histopathology and disease progression that mimic the human disease. To investigate differences in cellular bioenergetics between normal prostate epithelial cells and prostate tumor cells, in vivo MR spectroscopic (MRS) studies with non-proton nuclei, such as (13)C, in the TRAMP ...
متن کاملFast dynamic 3D MR spectroscopic imaging with compressed sensing and multiband excitation pulses for hyperpolarized 13C studies.
Hyperpolarized 13C MR spectroscopic imaging can detect not only the uptake of the pre-polarized molecule but also its metabolic products in vivo, thus providing a powerful new method to study cellular metabolism. Imaging the dynamic perfusion and conversion of these metabolites provides additional tissue information but requires methods for efficient hyperpolarization usage and rapid acquisitio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008