An anthropomorphic beating heart phantom for cardiac X‐ray CT imaging evaluation

نویسندگان

  • Thomas Boltz
  • William Pavlicek
  • Robert Paden
  • Markus Renno
  • Angela Jensen
  • Metin Akay
چکیده

The current work describes an anthropomorphic beating heart phantom constructed as a tool for the assessment of technological advances in cardiac x-ray computed tomography (CT). The phantom is comprised of a thorax, a compressor system, an ECG system, a beating heart with tortuous coronary arteries, and the option to add or remove pathologies such as aberrant beats, stents, and plaques. Initial trials with the phantom have shown its utility to assess temporal resolution, spatial resolution, radiation dose, iodine contrast, stents, and plaques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of the Beating Heart Based on Physically Modeling a Deformable Balloon

The motion of the beating heart is complex and creates artifacts in SPECT and x-ray CT images. Phantoms such as the Jaszczak Dynamic Cardiac Phantom are used to simulate cardiac motion for evaluation of acquisition and data processing protocols used for cardiac imaging. Two concentric elastic membranes filled with water are connected to tubing and pump apparatus for creating fluid flow in and o...

متن کامل

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

Phantom evaluation of a cardiac SPECT/VCT system that uses a common set of solid-state detectors for both emission and transmission scans

BACKGROUND We developed a cardiac SPECT system (X-ACT) with low dose volume CT transmission-based attenuation correction (AC). Three solid-state detectors are configured to form a triple-head system for emission scans and reconfigured to form a 69-cm field-of-view detector arc for transmission scans. A near mono-energetic transmission line source is produced from the collimated fluorescence x-r...

متن کامل

Development and Characterization of Synthetic Tissue- Equivalent Material for CT Imaging Applications

Introduction: The use of a simple tissue analog material in the fabrication of medical computed tomography (CT) imaging phantoms has great potential to help researchers. The purpose of the present study is to develop new gel tissue-equivalent materials and determine whether their CT numbers and relative electron densities vary in CT images obtained by scans at different energie...

متن کامل

Evaluation of a commercial cardiac motion phantom for dual‐energy chest radiography

Misregistration due to cardiac motion causes artifacts in two-exposure dual-energy subtraction images, in both the soft-tissue-only image and the bone-only image. Two previous investigations have attempted to avoid misregistration artifacts by using cardiac gating of the first and second exposures. The severity of misregistration was affected by the heart rate, the time interval between the low...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010