Heat capacity measurements of Sn nanostructures using a thin-film differential scanning calorimeter with 0.2 nJ sensitivity
نویسندگان
چکیده
We have developed a new thin-film differential scanning calorimetry technique that has extremely high sensitivity of 0.2 nJ. By combining two calorimeters in a differential measurement configuration, we have measured the heat capacity and melting process of Sn nanostructures formed via thermal evaporation with deposition thickness down to 1 Å. The equivalent resolution of the calorimeter is 1 nanogram in mass or 0.4 Å in thickness. We have observed a decrease of up to 120 °C in the melting point of Sn nanostructures. © 1997 American Institute of Physics. @S0003-6951~97!04301-5#
منابع مشابه
A novel on-chip three-dimensional micromachined calorimeter with fully enclosed and suspended thin-film chamber for thermal characterization of liquid samples.
A microfabricated calorimeter (μ-calorimeter) with an enclosed reaction chamber is presented. The 3D micromachined reaction chamber is capable of analyzing liquid samples with volume of 200 nl. The thin film low-stress silicon nitride membrane is used to reduce thermal mass of the calorimeter and increase the sensitivity of system. The μ-calorimeter has been designed to perform DC and AC calori...
متن کاملUltrasensitive, fast, thin-film differential scanning calorimeter
The equipment for an ultrasensitive, fast, thin-film differential scanning calorimetry @~TDSC! or nanocalorimetry# technique is described. The calorimetric cell ~;0.30 cm! operates by applying a short ~;10 ms! dc current pulse ~;10 mA! to a thin ~;50 nm! patterned metal strip, which is supported by a thin ~;50 nm! SiNx membrane. The calorimeter operates at high heating rates ~15–200 K/ms! and i...
متن کاملInvestigating the thermodynamics and kinetics of thin film reactions by differential scanning calorimetry
In this paper we demonstrate the utility of differential scanning calorimetry for investigating the thermodynamics and kinetics of a broad range of thin film reactions. We begin by describing differential scanning calorimeters and the preparation of thin film samples. We then cite a number of examples that illustrate how enthalpies of crystallization, heats of formation and enthalpies of interf...
متن کاملOrganic Thin Film Transistors with Polyvinylpyrrolidone / Nickel Oxide Sol-Gel Derived Nanocomposite Insulator
Polyvinylpyrrolidone / Nickel oxide (PVP/NiO) dielectrics were fabricated with sol-gel method using 0.2 g of PVP at different working temperatures of 80, 150 and 200 ºC. Structural properties and surface morphology of the hybrid films were investigated by X- Ray diffraction (XRD) and Scanning Electron Microscope (SEM) respectively. Energy dispersive X-ray spec...
متن کاملHigh - speed ( 104 ° C / s ) scanning microcalorimetry with monolayer sensitivity ( J / m 2 )
We introduce a high sensitivity (1J/m) scanning microcalorimeter that can be used at high heating rates (10 °C/s). The system is designed using ultrathin SiN membranes that serve as a low thermal mass mechanical support structure for the calorimeter. Calorimetry measurements of the system are accomplished via resistive heating techniques applied to a thin film Ni heating element that also serve...