Anatomic Locking Plate Fixation for Scaphoid Nonunion

نویسندگان

  • Joshua Mirrer
  • Just Yeung
  • Anthony Sapienza
چکیده

Nonunion can occur relatively frequently after scaphoid fracture and appears to be associated with severity of injury. There have been a number of techniques described for bone grafting with or without screw fixation to facilitate fracture healing. However, even with operative fixation of scaphoid fractures with bone grafting nonunion or malunion rates of 5 to 10 percent are still reported. This is the first report of an anatomic locking plate for scaphoid fracture repair in a 25-year-old right hand dominant healthy male.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

Short report letter: Three-dimensional printed anatomical models in scaphoid surgery

When undertaking surgery for nonunion of scaphoid fractures, appreciation of the three dimensional (3D) anatomy and hence accurate restoration of the original shape of the bone is difficult. Computerised tomography (CT) is regularly used to evaluate scaphoid nonunions slice by slice before surgery. As a potential aid for surgical planning, we have developed a method for producing 3D printed ana...

متن کامل

Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus varianc...

متن کامل

Tibiotalocalcaneal Arthrodesis Using a Femoral Locking Plate

The goal of a tibiotalocalcaneal arthrodesis is to create a pain-free, stable hindfoot and ankle. Although a reserved procedure, it is useful when simultaneous ankle and subtalar joint pathology exists. Numerous complications have been reported after tibiotalocalcaneal arthrodesis, most importantly nonunion. Locking plates have proved to be a more stable construct than alternative forms of arth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016