Determination of carbon in aqueous solutions by atmospheric-pressure helium microwave induced plasma atomic emission spectrometry with gas-phase sample introduction technique.

نویسندگان

  • Akihiro Matsumoto
  • Taketoshi Nakahara
چکیده

A trace amount of carbon was determined by atmospheric-pressure helium microwave induced plasma atomic emission spectrometry (He-MIP-AES) with gas-phase sample introduction technique. This method was applied for the generation of a continuous flow of carbon dioxide by the acidification of carbonate ion and hydrogen carbonate ion for the determination of carbon. The generated carbon dioxide was separated from the solution by a simple gas-liquid separator, dried with a desiccant and swept into the MIP with helium carrier gas for analysis. Of the acids and drying agents investigated, hydrochloric acid for acidification and anhydrous calcium chloride as a desiccant were found to be the most appropriate for the generation of carbon dioxide. Under the optimized experimental conditions, the best attainable detection limits at C (I) 193.09 and C (I) 247.86 nm lines were 7.89 and 8.10 microg/l with linear dynamic ranges of 100 to 10,000 and 100 to 20,000 microg/l for carbon, respectively. The presence of many diverse elements and ions was found to cause a more or less depressing interference by the proposed technique. However, no interference was observed from the following elements and ions: Ca, K, Rb, Br-, Cl-, F- and I-. Finally, the present method has been applied to the determination of carbon in several water samples.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characteristics of Helium Microwave-Induced Atmospheric Pressure Plasma for Fine Particle Analysis

Helium microwave-induced plasma (He-MIP) for trace element analysis is generated by a 2.45 GHz microwave power ( ~ 1 kW) with the Okamoto cavity of the surface wave mode at atmospheric pressure, and an iron excitation temperature and an electron density of the plasma are measured. With 0.8 kW input microwave power, an excitation temperature of 8000 K and the electron density of 2 x 10/cm are ob...

متن کامل

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Effects of cold atmospheric plasma on viability of breast (MDA-MB-231) and cervical (Hela) cancer cells

Introduction: There are many reports published about the use of cold atmospheric plasma in cancer treatment recently. In this way, the selective effects of cold plasma on the breast (MDA-MB-231) and cervical (Hela) cancer cells were studied as a new cancer treatment method. Materials and Methods: In this study, cold atmospheric pressure plasma was generated using a plasma jet reactor and also o...

متن کامل

Determination of I/I isotope ratios in liquid solutions and environmental soil samples by ICP-MS with hexapole collision cell

The determination of I in environmental samples at ultratrace levels is very difficult by ICP-MS due to a high noise caused by Xe impurities in argon plasma gas (interference of Xe), possible IH2 1 interference and an insufficient abundance ratio sensitivity of the ICP mass spectrometer for I/I isotope ratio measurement. A sensitive, powerful and fast analytical technique for iodine isotope rat...

متن کامل

Microwave induced plasmas as sources for atomic spectrometry

Microwave induced plasmas (MIPs) have been studied for their potential applicability as analytical sources for over 20 years. In 1965 the MIP was described as an elemental emission detector for gas chromatography (GC) by McCormack and coworkers [1]. Because of its initial low power operation of less than 100 Watts, this plasma, with He primarily as the plasma gas, has been most successfully app...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2003