Visualization of the trochlear nerve in the cistern with use of high-resolution turbo spin-echo multisection motion-sensitized driven equilibrium.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The trochlear nerve is so thin that it is rarely observed with MR imaging. Therefore, we used high-resolution MSDE to reliably visualize the cisternal segments of the trochlear nerve. MATERIALS AND METHODS Participants were 10 healthy young adults (mean age, 24 years), and 20 trochlear nerves were examined. HR-MRC, BS-MRC, and HR-MSDE were performed. A neuroradiologist judged the visibility of the trochlear nerves as 1 of 4 grades ("Excellent," "Good," "Fair," and "Not") in each MR imaging sequence. The findings were then statistically analyzed with the χ(2) test. RESULTS Of all 20 trochlear nerves, 6 with HR-MRC, 13 with BS-MRC, and 18 with HR-MSDE were judged as "Excellent." CSF flow-related artifacts and vessels in the cistern and cerebellar tentorium in HR-MRC tended to prevent the neuroradiologists from identifying the trochlear nerve. Vessels in the cistern and cerebellar tentorium in BS-MRC also tended to prevent the neuroradiologists from identifying the trochlear nerve. Compared with other sequences, HR-MSDE visualized the trochlear nerve more often. The χ(2) test revealed statistically significant differences among the 3 MR imaging sequences (P < .01). The scan time of HR-MSDE was approximately 1.5-2.2 times longer than that of the other sequences. CONCLUSIONS HR-MSDE is able to clearly visualize the trochlear nerve and has the same or better ability to delineate the trochlear nerve compared with other MR imaging sequences, though its long scan time does not yet yield practical use.
منابع مشابه
Improvement of T1 contrast in whole-brain black-blood imaging using motion-sensitized driven-equilibrium prepared 3D turbo spin echo (3D MSDE-TSE).
We demonstrated a new scheme for performing the T1-enhanced whole-brain black-blood imaging pulse sequence using motion-sensitized driven-equilibrium prepared 3-dimensional (3D) turbo spin echo (MSDE-TSE) with anti-driven-equilibrium post pulse. The use of an anti-driven-equilibrium pulse considerably improved the T1 contrast of MSDE-TSE black-blood images. This sequence can be used for whole-b...
متن کاملTransition into driven equilibrium of the balanced steady-state free precession as an ultrafast multisection T2-weighted imaging of the brain.
BACKGROUND AND PURPOSE Current T2-weighted imaging takes >3 minutes to perform, for which the ultrafast transition into driven equilibrium (TIDE) technique may be potentially helpful. This study qualitatively and quantitatively evaluates the imaging of transition into driven equilibrium of the balanced steady-state free precession (TIDE) compared with TSE and turbo gradient spin-echo on T2-weig...
متن کاملEvaluation of diffusivity in the anterior lobe of the pituitary gland: 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation.
BACKGROUND AND PURPOSE 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation is a non-echo-planar technique for DWI, which enables high-resolution DWI without field inhomogeneity-related image distortion. The purpose of this study was to evaluate the feasibility of diffusion-sensitized driven-equilibrium turbo field echo in evaluating diffusivity in the normal pituitary g...
متن کاملFree-breathing 3D whole-heart black-blood imaging with motion sensitized driven equilibrium.
PURPOSE To assess the efficacy and robustness of motion sensitized driven equilibrium (MSDE) for blood suppression in volumetric 3D whole-heart cardiac MR. MATERIALS AND METHODS To investigate the efficacy of MSDE on blood suppression and myocardial signal-to-noise ratio (SNR) loss on different imaging sequences, seven healthy adult subjects were imaged using 3D electrocardiogram (ECG)-trigge...
متن کاملAssessment of improved motion-sensitized driven equilibrium (iMSDE) for multi-contrast vessel wall screening.
PURPOSE We assessed the improved motion-sensitized driven equilibrium (iMSDE) technique for multiple contrast 3-dimensional vessel wall imaging at 3T. METHODS Carotid images were obtained using iMSDE combined with turbo field echo (iMSDE-TFE) and conventional double inversion-recovery turbo spin-echo (DIR-TSE) in 5 healthy adult subjects. The tissue signal-to-noise efficiency (SNReff), SNR di...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 34 7 شماره
صفحات -
تاریخ انتشار 2013