Vascular guide wire navigation with a magnetic guidance system: experimental results in a phantom.

نویسندگان

  • Mirko Schiemann
  • Reinmar Killmann
  • Martin Kleen
  • Nasreddin Abolmaali
  • Jennifer Finney
  • Thomas J Vogl
چکیده

PURPOSE To investigate the efficacy of a second-generation prototype magnetic guidance system in complex vessel phantoms versus conventional navigation in simulated interventional radiology procedures and to analyze procedure and fluoroscopy times. MATERIALS AND METHODS The magnetic guidance system consists of two focused-field permanent magnets on each side of the body that create a 0.1-T navigation field and is integrated with a modified C-arm single-planar digital angiography system. Forty-nine navigations in a glass phantom and 80 navigations in a three-dimensional liver phantom were performed with a magnetically tipped floppy 0.014-inch guide wire and a conventional 0.014-inch microcatheter system. Rates of success and fluoroscopy and procedure times were quantified for both techniques. For the liver phantom experiment, the Mann-Whitney U test was used. For the glass phantom experiment, the Wilcoxon matched pair test was used with the Hodges-Lehmann estimator. RESULTS In the glass phantom experiments, 42 of 49 turns were successfully performed with both methods. Procedure time to reach a target did not differ significantly between methods, while fluoroscopy time was significantly different when compared with that of the magnetic guidance system (P <.01). Navigation in the liver phantom was successful in 80 of 80 turns with the magnetic guidance system and in 76 of 80 turns with conventional navigation. With the support of the magnetic guidance system, procedure time and fluoroscopy time were significantly different from those with conventional navigation (P <.001). CONCLUSION The magnetic guidance system allows the precise navigation of a magnetic guide wire in complex vessel phantoms with significantly shorter fluoroscopy and procedure times.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of magnetic field‐guided navigation system for interventional neurosurgical and cardiac procedures

A hospital-based magnetic guidance system (MGS) was installed to assist a physician in navigating catheters and guide wires during interventional cardiac and neurosurgical procedures. The objective of this study is to examine the performance of this magnetic field-guided navigation system. Our results show that the system's radiological imaging components produce images with quality similar to ...

متن کامل

Newly Designed Sheaths for Gastroduodenal Intervention: An Experimental Study in a Phantom and Dogs

OBJECTIVE To evaluate the usefulness of newly designed sheaths for gastroduodenal intervention in a gastric phantom and dogs. MATERIALS AND METHODS A regular sheath was made using a polytetrafluoroethylene tube (4 mm in diameter, 90 cm long) with a bent tip (4 cm long, 100 degree angle). For the supported type of sheath, a 5 Fr catheter was attached to a regular sheath to act as a side lumen....

متن کامل

3D Dynamic Roadmapping for Abdominal Catheterizations

Despite rapid advances in interventional imaging, the navigation of a guide wire through abdominal vasculature remains, not only for novice radiologists, a difficult task. Since this navigation is mostly based on 2D fluoroscopic image sequences from one view, the process is slowed down significantly due to missing depth information and patient motion. We propose a novel approach for 3D dynamic ...

متن کامل

A Modified Proportional Navigation Guidance for Accurate Target Hitting

When a detector sensitive to the target plume IR seeker is used for tracking airborne targets, the seeker tends to follow the target hot point which is a point farther away from the target exhaust and its fuselage. In order to increase the missile effectiveness, it is necessary to modify the guidance law by adding a lead bias command. The resulting guidance is known as target adaptive guidance ...

متن کامل

حل مشکل جاگذاری کاتتر ورید مرکزی با استفاده از کاتتر وریدی: مقاله تکنیکال

Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 232 2  شماره 

صفحات  -

تاریخ انتشار 2004