Advances and Clinical Applications of Anterior Segment Imaging Techniques
نویسندگان
چکیده
With the rapid development of computer science and technologies in recent years, there has been dramatic advance in anterior segment imaging. As we have mentioned in the call for papers for this special issue, manuscripts are covering the topics of anterior segment imaging techniques including anterior segment optical coherence tomography (OCT), specular microscopy, corneal topography, confocal microscopy, and ultrasound biomi-croscopy (UBM). These techniques have enabled precise visualization and objective assessments of anterior segment structures; thus, these devices have become essential tools for better diagnosis and treatment of anterior segment diseases including corneal disorders, cataract, glaucoma, and even disorders of the lacrimal system. Future development of novel modalities, that is, en face OCT or ultrahigh-resolution OCT, is expected to allow more detailed visualization at a microscopic level, which would provide even more understanding of anterior segment pathology at a cellular level. In this special issue, the authors contributed 15 original articles and 4 review papers regarding technologies of the anterior segment imaging and clinical application of the imaging devices. The authors have contributed the results of their original researches on various topics on anterior segment imaging: (1) agreement between gonioscopic examination and swept source OCT imaging; (2) preliminary outcomes of accelerated corneal collagen cross-linking using topography-guided ultraviolet-A energy emission; (3) anterior segment changes before and following laser peripheral iridotomy of iris bombe in patients with uveitic secondary glaucoma; (4) anterior segment measurements with swept source OCT before and after ab interno trabeculotomy; (5) effects of a new type implantable collamer lens implantation on vision-related daily activities; (6) corneal epithelial remodeling after transepithelial photorefractive keratectomy for myopia; (7) measurement of anterior chamber volume in cataract patients using swept-source OCT; (8) biomechanical findings in contact lens-induced corneal warpage; (9) quantitative analysis of lens nuclear density using OCT with a liquid optics interface; (10) rotating Scheimpflug imaging indices in different grades of keratoconus; (11) evaluation of outflow structures in vivo after the phacocanaloplasty; (12) evaluation of corneal epithelial thickness in asymmetric keratoconic eyes and normal eyes using Fourier domain OCT; (13) central corneal thickness measured using spectral-domain OCT and associations with ocular and systemic parameters; (14) anterior segment changes in pseudophakic eyes after pars plana vitrectomy with silicone oil or gas tamponade using UBM imaging; and (15) UBM comparison of ab interno and ab externo intraocular lens scleral fixation. This special issue also includes review articles on the following topics: (1) application of Scheimpflug …
منابع مشابه
Real-time optical coherence tomography of the anterior segment at 1310 nm.
BACKGROUND Recent advances in high-speed scanning technology have enabled a new generation of optical coherence tomographic (OCT) systems to perform imaging at video rate. Here, a handheld OCT probe capable of imaging the anterior segment of the eye at high frame rates is demonstrated for the first time. OBJECTIVE To demonstrate real-time OCT imaging of anterior segment structures. DESIGN S...
متن کاملRecent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملAqueous Humor Outflow Structure and Function Imaging At the Bench and Bedside: A Review
Anterior segment glaucoma clinical care and research has recently gained new focus because of novel imaging modalities and the advent of angle-based surgical treatments. Traditional investigation drawn to the trabecular meshwork now emphasizes the entire conventional aqueous humor outflow (AHO) pathway from the anterior chamber to the episcleral vein. AHO investigation can be divided into struc...
متن کاملSWI: Probe for neuroradiologists
Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...
متن کاملSWI: Probe for neuroradiologists
Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016