Measuring frequency noise and intrinsic linewidth of a room-temperature DFB quantum cascade laser.
نویسندگان
چکیده
The frequency-noise power spectral density of a room-temperature distributed-feedback quantum cascade laser emitting at λ = 4.36 μm has been measured. An intrinsic linewidth value of 260 Hz is retrieved, in reasonable agreement with theoretical calculations. A noise reduction of about a factor 200 in most of the frequency interval is also found, with respect to a cryogenic laser at the same wavelength. A quantitative treatment shows that it can be explained by a temperature-dependent mechanism governing the transport processes in resonant tunnelling devices. This confirms the predominant effect of the heterostructure in determining shape and magnitude of the frequency noise spectrum in QCLs.
منابع مشابه
Effects of resonant tunneling and dynamics of coherent interaction on intrinsic linewidth of quantum cascade lasers
A theoretical model for calculation of the intrinsic linewidth of QCLs is built on the basis of the quantum Langevin approach. It differs from the traditional rate equation model in that the resonant tunneling and the dynamics of coherent interaction can be considered. Results show that the coupling strength and the dephasing rate associated with resonant tunneling strongly affect the linewidth...
متن کاملTemperature dependence of the frequency noise in a mid-IR DFB quantum cascade laser from cryogenic to room temperature.
We report on the measurement of the frequency noise power spectral density in a distributed feedback quantum cascade laser over a wide temperature range, from 128 K to 303 K. As a function of the device temperature, we show that the frequency noise behavior is characterized by two different regimes separated by a steep transition at ≈200 K. While the frequency noise is nearly unchanged above 20...
متن کاملFrequency noise of free-running 4.6 μm distributed feedback quantum cascade lasers near room temperature.
The frequency noise properties of commercial distributed feedback quantum cascade lasers emitting in the 4.6 μm range and operated in cw mode near room temperature (277 K) are presented. The measured frequency noise power spectral density reveals a flicker noise dropping down to the very low level of <100 Hz(2)/Hz at 10 MHz Fourier frequency and is globally a factor of 100 lower than data recen...
متن کاملDirect link of a mid-infrared QCL to a frequency comb by optical injection.
A narrow-linewidth comb-linked nonlinear source is used as master radiation to injection lock a room-temperature mid-infrared quantum cascade laser (QCL). This process leads to a direct lock of the QCL to the optical frequency comb, providing the unique features of narrow linewidth, absolute frequency, higher output power, and wide mode-hop-free tunability. The QCL reproduces the injected radia...
متن کاملCFA 8 : OO am - 9 : 45 am Room : 101 B Laser - Based Gas and Chemical Sensing
A compact, tunable mid-IR laser source is the most critical opto-electronic component in a spectroscopic molecular sensor. Until recently, the choice of such sources was limited to cryogenically cooled Pb-salt diode lasers and lowpower devices based on difference frequency generation (DFG). The development of quantum cascade (QC) lasers and especially single-frequency devices with distributed f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 19 19 شماره
صفحات -