Intriguing peri-strut low-intensity area detected by optical coherence tomography after coronary stent deployment.

نویسندگان

  • Tomohiko Teramoto
  • Fumiaki Ikeno
  • Hiromasa Otake
  • Jennifer K Lyons
  • Heleen M M van Beusekom
  • William F Fearon
  • Alan C Yeung
چکیده

BACKGROUND Although peri-strut low-intensity area (PLIA) is frequently observed on post-stenting optical coherence tomography (OCT) images, the histology associated with PLIA is undocumented. METHODS AND RESULTS The 36 porcine coronary lesions treated with bare-metal (BMS: n=16) or drug-eluting (DES: n=20) stents were assessed by OCT and histology at 28 days. DES showed a significantly higher incidence of PLIA than BMS. Also, +PLIA stents had greater neointima than PLIA stents. Histological analysis revealed the existence of fibrinoid and proteoglycans at the site of PLIA. CONCLUSIONS PLIA might be represented by the presence of fibrinoid and proteoglycans, and associated with neointimal proliferation after stenting.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Characteristics and Prognosis of Peri-strut Low-intensity Area Detected by Optical Coherence Tomography

BACKGROUND Peri-strut low-intensity area (PLIA) is a typical image pattern of neointima detected by optical coherence tomography (OCT) after stent implantation. However, few studies evaluated the predictors and prognosis of the PLIA; therefore, we aimed to explore the genesis and prognosis of PLIA detected by OCT in this study. METHODS Patients presenting neointimal hyperplasia documented by ...

متن کامل

Coronary evaginations and peri-scaffold aneurysms following implantation of bioresorbable scaffolds: incidence, outcome, and optical coherence tomography analysis of possible mechanisms.

BACKGROUND Peri-stent coronary evaginations may disturb flow and have been proposed as possible risk factor for late stent thrombosis. We describe incidence, predictors, and possible mechanisms of coronary evaginations 12 months after implantation of bioresorbable vascular scaffolds (BVS). METHODS AND RESULTS One hundred and two BVS implanted in 90 patients (age 63 ± 13 years, 71 males, 14 di...

متن کامل

Histological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation.

Novel polymer-free drug-eluting stents have been developed to reduce polymer-related adverse events. However, neointimal coverage after polymer-free DES implantation is unclear and validation between optical coherence tomography (OCT) and histology is required. Sixteen polymer-free sirolimus-eluting stents were randomly implanted into coronary arteries of 8 normal swine. OCT and histological me...

متن کامل

Prolonged high-pressure is required for optimal stent deployment as assessed by optical coherence tomography.

AIMS Optimizing stent deployment is important for both acute- and long-term outcomes. High-pressure balloon inflation is the standard for coronary stent implantation. However, there is no standardized inflation protocol. We hypothesized that prolonged high-pressure balloon inflation until stabilization of inflation pressure is superior to a rapid inflation/deflation sequence for both stent expa...

متن کامل

Randomized comparison of stent strut coverage following angiography- or optical coherence tomography-guided percutaneous coronary intervention.

INTRODUCTION AND OBJECTIVES The clinical benefits of optical coherence tomography-guided percutaneous coronary intervention are unclear. Therefore, in this study we sought to evaluate the impact of optical coherence tomography guidance on stent strut coverage following drug-eluting stent implantation. METHODS A total of 101 patients in 105 lesions were randomly assigned to receive percutaneou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 74 6  شماره 

صفحات  -

تاریخ انتشار 2010