In Vw0 Digital Phyto Imaging (idpi) in Juglans
نویسندگان
چکیده
A major disadvantage of conventional seed radiography is that the resulting image will not distinguish full-viable seeds from full-nonviable. Empty seeds will imbibe sufficient water to appear full, but these are easily distinguished by radiography before imbibition. Full seeds, both viable and nonviable, have 25 to 35% moisture content when freshly collected. This is sufficient water to confuse interpretation due to radiopacity of water density. While the full-viable seeds will germinate, the full-nonviable ones will not germinate due to physiological rather than morphological conditions, even while they maintain a moisture content sufficient to support germination. Speculation points to distribution and availability of free water and fat as promising factors to determine if an otherwise healthy seed will germinate. Magnetic resonance imaging (MRI) will determine these distributions. MRI is a nondestructive, noninvasive method suitable to seed research and ultimate germination of viable seeds. Although it is a widely used medical procedure, there are only limited applications to tree seed physiology. Specific differences reported in this paper are primarily the distribution and abundance of mobile hydrogen (H+) protons in bulk free water and in lipid molecules or parts of long chains. The difference in images was obtained by using fat and water suppression techniques utilising the small differences in resonant frequencies between H+ in bulk water and lipids.
منابع مشابه
A Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology
Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and pr...
متن کاملThe Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality
Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality. Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...
متن کاملAgreement of Bitewing and Digital Panoramic Radiographies in the Detection of Proximal Caries
Background & Aims: Conventional radiography is used for the diagnosis of problems such as dental caries and failure in root canal therapy. The diagnosis accuracy of conventional radiography is acceptable in the evaluation of anatomical and pathological structures. However, it seems that by using digital radiography we can obtain more information in this field. The aim of this study is to compar...
متن کاملSepration and determination trace amount of cadmium ions in real and water samples by cloud point extraction - flame atomic absorption spectrophotometry after preconcentration with non-ionic surfactant Triton-X114
2-(3- indolyl) – 4,5 di phynyl imidazole.(IDPI) was used as a complexing agent in cloud point extraction for the first time and applied for selective pre-concentration of trace amounts of cadmium. The method is based on the extraction of cadmium at pH= 7.0 by using non-ionic surfactant Triton-X114 and 2-(3- indolyl) – 4,5 di phynyl imidazole. (IDPI) as a chelating agent. The adopted concentrati...
متن کاملComparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption
Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2000