Pulsed acceleration charge detection mass spectrometry: application to weighing electrosprayed droplets.
نویسندگان
چکیده
We describe a new approach to measuring the masses of individual macroions. The method employs a pulsed acceleration tube located between two sensitive image charge detectors. The charge and velocity of the macroion are recorded with the first image charge detector. The ion is pulse accelerated through a known voltage drop, and then the charge and velocity are remeasured using the second image charge detector. The mass of the ion is deduced from its charge and its initial and final velocities. The approach has been used to measure masses in the 10(10)-10(14) Da range with z = 10(3)-10(6) and m/z = 10(6)-10(9). It should be extendable to masses of <10(6) Da. We have used the method to determine the size and charge of water droplets transmitted through a capillary interface and an aperture interface. The droplets detected from the aperture interface are approximately 1 order of magnitude smaller in mass than those detected from the capillary interface. The droplets from both interfaces have relatively low charges, particularly with the capillary interface where they are only charged to a small fraction of the Rayleigh limit. These results suggest that the aerodynamic breakup of the droplets plays a significant role in the mechanism of electrospray ionization.
منابع مشابه
Charge separation in the aerodynamic breakup of micrometer-sized water droplets.
Charged water droplets generated by electrospray, sonic spray, and a vibrating orifice aerosol generator (VOAG) have been studied by digital macrophotography and image charge detection mass spectrometry. Image charge detection mass spectrometry provides information on the droplet size, charge, and velocity after transmission through a capillary interface. The digital images provide the droplet ...
متن کاملProtein fluorescence measurements within electrospray droplets.
The conformation of cytochrome c molecules within electrospray droplets is investigated by monitoring the laser induced fluorescence of its single tryptophan residue (Trp-59). By increasing the alcohol concentration of the electrosprayed solutions, protein denaturation is induced, giving rise to significant changes in the intensity of the detected fluorescence. Comparison with analogous denatur...
متن کاملNegative droplets from positive electrospray.
Image charge detection has been used to measure the charge and velocity of individual electrosprayed water droplets. With a positive bias on the electrospray needle the majority of the droplets are, as expected, positively charged. However, a small fraction, surprisingly, carry a negative charge. Plausible explanations for the presence of the negatively charged droplets are discussed. In partic...
متن کاملMass spectrometry sampling under ambient conditions with desorption electrospray ionization.
A new method of desorption ionization is described and applied to the ionization of various compounds, including peptides and proteins present on metal, polymer, and mineral surfaces. Desorption electrospray ionization (DESI) is carried out by directing electrosprayed charged droplets and ions of solvent onto the surface to be analyzed. The impact of the charged particles on the surface produce...
متن کاملDesorption Electrospray Ionization (DESI)
A new method of desorption ionization is described and applied to the ionization of various compounds, including peptides and proteins present on metal, polymer, and mineral surfaces. Desorption electrospray ionization (DESI) is carried out by directing electrosprayed charged droplets and ions of solvent onto the surface to be analyzed. The resulting mass spectra are similar to normal ESI mass ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 79 22 شماره
صفحات -
تاریخ انتشار 2007