Pediatric impedance cardiography: temporal stability and intertask consistency.

نویسندگان

  • J J McGrath
  • W H O'Brien
چکیده

The pathogenic processes responsible for cardiovascular disease have their origins in childhood. Although children's measures of heart rate and blood pressure have been found to be reliable, the reliability of impedance cardiography derived measures have not been evaluated. Thirty-three children, ages 8-11 participated in two sessions. Stressors included serial subtraction, isometric handgrip, and mirror-image tracing. Results indicated the impedance measures showed moderately high temporal stability (average scores r(avg) = .74; difference scores r(avg) = .53) and intertask consistency (average scores r(avg)= .78; difference scores r(avg)= .53). Blood pressure demonstrated the lowest reliability; Heather index, preejection period, and stroke volume demonstrated the highest. These findings suggest children's cardiovascular reactivity to laboratory stressors can be reliably and consistently assessed using impedance cardiography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temporal stability of ambulatory stroke volume and cardiac output measured by impedance cardiography.

UNLABELLED Recently, devices have become available that allow non-invasive measurement of stroke volume and cardiac output through ambulatory thorax impedance recording. If such recordings have adequate temporal stability, they offer great potential to further our understanding of how repeated or chronic cardiovascular activation in response to naturalistic events may contribute to cardiovascul...

متن کامل

Stability of children's and adolescents' hemodynamic responses to psychological challenge: a three-year longitudinal study of a multiethnic cohort of boys and girls.

This report evaluated (a) the temporal stability of hemodynamic responses to three tasks using impedance cardiography, and (b) the influence of aging on stress responses in a multi-ethnic pediatric sample. One hundred children 8 to 10 years old and 49 adolescents 15 to 17 years old were tested at study entry and on average 3 years later. Results showed that the composite task-induced changes in...

متن کامل

Measurement of lung function using Electrical Impedance Tomography (EIT) during mechanical ventilation

The consistency of regional lung density measurements as estimated by Electrical Impedance Tomography (EIT), in eleven patients supported by a mechanical ventilator, was validated to verify the feasibility of its use in intensive care medicine. There were significant differences in regional lung densities between the normal lung and diseased lungs associated with pneumonia, atelectasis and pleu...

متن کامل

Head-up-tilt testing in children: new perspectives using beat-to-beat blood-pressure monitoring

The head-up-tilt-test in pediatric patients for the evaluation of syncope shows a sensitivity of 35-85% and often requires pharmacological stimulation in order to improve its diagnostic value. We used a new device for beat-to-beat blood pressure monitoring combined with impedance cardiography in a 12-year-old girl during tilt testing. A seven seconds asystolia was provoked. The haemodynamic par...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Psychophysiology

دوره 38 3  شماره 

صفحات  -

تاریخ انتشار 2001