Atrial vs. dual-chamber cardiac pacing in sinus node disease: a register-based cohort study.

نویسندگان

  • C Michael Fored
  • Fredrik Granath
  • Fredrik Gadler
  • Paul Blomqvist
  • Jenny Rynder
  • Cecilia Linde
  • Anders Ekbom
  • Mårten Rosenqvist
چکیده

AIMS In patients with sinus node disease, dual-chamber pacing (DDD) possibly results in adverse effects on the ventricular function. We have compared the incidence of cardiovascular morbidity and mortality in patients with sinus node disease and with atrioventricular (AV) synchronous pacemakers, DDD vs. atrial pacing (AAI). METHODS AND RESULTS A nation-wide population-based cohort of 8777 patients with AAI- or DDD-mode pacemakers was followed during 12 years. The cohort was linked to national healthcare and census registers. Patients with DDD pacing and without any pre-implant admission for atrial fibrillation or flutter had an increased risk of post-implant fibrillation or flutter, in relation to corresponding AAA patients [hazard ratio (HR) = 1.30; 95% confidence interval (CI) 1.10-1.52]. A slight increase in the risk of any cardiovascular disease (HR = 1.07; CI, 1.00-1.15), and all-cause mortality (HR = 1.12; CI, 1.00-1.25), was seen among DDD patients, in relation to AAI patients, but there was no significant difference in the risk of ischaemic or unspecified stroke (HR = 1.14; CI, 0.94-1.37). Among DDD patients, the all-cause mortality did not differ from the general population [standardized mortality ratio (SMR) = 1.04; CI, 0.98-1.11]. Patients with AAI, however, had a decreased all-cause mortality risk (SMR = 0.89; CI, 0.82-0.97). CONCLUSION Our results support AAI as the preferred mode of pacing in patients with sinus node disease, and a normal AV node function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual chamber cardiac pacing in children: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker?

BACKGROUND Dual chamber pacemakers (single chamber pacing dual chamber sensing cardiac pacemaker (VDD) and dual chamber pacing and sensing cardiac pacemaker (DDD)) are being used frequently in children and adolescents. The aim of this study was to verify the safety and performance of the VDD and DDD pacing systems, and to evaluate the differences between two pacing modes with regard to atrial s...

متن کامل

Long-Term Outcome of Single-Chamber Atrial Pacing Compared with Dual-Chamber Pacing in Patients with Sinus-Node Dysfunction and Intact Atrioventricular Node Conduction

PURPOSE The optimal pacing mode with either single chamber atrial pacemaker (AAI or AAIR) or dual chamber pacemaker (DDD or DDDR) is still not clear in sinus-node dysfunction (SND) and intact atrioventricular (AV) conduction. MATERIALS AND METHODS Patients who were implanted with permanent pacemaker using AAI(R) (n = 73) or DDD(R) (n = 113) were compared. RESULTS The baseline characteristic...

متن کامل

Ventricular pacing or dual-chamber pacing for sinus-node dysfunction.

BACKGROUND Dual-chamber (atrioventricular) and single-chamber (ventricular) pacing are alternative treatment approaches for sinus-node dysfunction that causes clinically significant bradycardia. However, it is unknown which type of pacing results in the better outcome. METHODS We randomly assigned a total of 2010 patients with sinus-node dysfunction to dual-chamber pacing (1014 patients) or v...

متن کامل

Atrial lead placement at the lower atrial septum: a potential strategy to reduce unnecessary right ventricular pacing.

AIMS Right ventricular (RV) pacing has been shown to be potentially detrimental to left ventricular function. In conventional dual-chamber pacing the position of the atrial lead could influence duration of the atrio-ventricular (AV) intervals, which is one of the variables that could be associated with an increased percentage of RV pacing. We wanted to see if lead placement at selected atrial s...

متن کامل

Dual chamber pacing mode in an atrial antitachycardia pacing device without a ventricular lead - A necessary evil.

We present a case of a single chamber atrial pacemaker implanted for sinus node dysfunction and treatment of macroreentrant atrial tachycardias with atrial antitachycardia pacing. The patient presented with sustained atrial tachycardia above the detection rate, however, the device was unable to detect the tachycardia and did not deliver the programmed therapy. We discuss the nuances of the atri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 10 7  شماره 

صفحات  -

تاریخ انتشار 2008