Stray Light Artifacts in Imagery from the Landsat 8 Thermal Infrared Sensor
نویسندگان
چکیده
The Thermal Infrared Sensor (TIRS) has been collecting imagery of the Earth since its launch aboard Landsat 8 in early 2013. In many respects, TIRS has been exceeding its performance requirements on orbit, particularly in terms of noise and stability. However, several artifacts have been observed in the TIRS data which include banding and absolute calibration discrepancies that violate requirements in some scenes. Banding is undesired structure that appears within and between the focal plane array assemblies. In addition, in situ measurements have shown an error in the TIRS absolute radiometric calibration that appears to vary with season and location within the image. The source of these artifacts has been determined to be out-of-field radiance that scatters onto the detectors thereby adding a non-uniform signal across the field-of-view. The magnitude of this extra signal can be approximately 8% or higher (band 11) and is generally twice as large in band 11 as it is in band 10. A series of lunar scans were obtained to gather information on the source of this out-of-field radiance. Analyses of these scans have produced a preliminary map of stray light, or ghost, source locations in the TIRS out-of-field area. This dataset has been used Remote Sens. 2014, 11 10436 to produce a synthetic TIRS scene that closely reproduces the banding effects seen in actual TIRS imagery. Now that the cause of the banding has been determined, a stray light optics model is in development that will pin-point the cause of the stray light source. Several methods are also being explored to correct for the banding and the absolute calibration error in TIRS imagery.
منابع مشابه
Radiometric Calibration Methodology of the Landsat 8 Thermal Infrared Sensor
The science-focused mission of the Landsat 8 Thermal Infrared Sensor (TIRS) requires that it have an accurate radiometric calibration. A calibration methodology was developed to convert the raw output from the instrument into an accurate at-aperture radiance. The methodology is based on measurements obtained during component-level and instrument-level characterization testing. The radiometric a...
متن کاملOn-Orbit Radiometric Performance of the Landsat 8 Thermal Infrared Sensor
The Thermal Infrared Sensor (TIRS) requirements for noise, stability, and uniformity were designed to ensure the radiometric integrity of the data products. Since the launch of Landsat 8 in February 2013, many of these evaluations have been based on routine measurements of the onboard calibration sources, which include a variable-temperature blackbody and a deep space view port. The noise equiv...
متن کاملLandsat-8 Thermal Infrared Sensor (TIRS) Vicarious Radiometric Calibration
Launched in February 2013, the Landsat-8 carries on-board the Thermal Infrared Sensor (TIRS), a two-band thermal pushbroom imager, to maintain the thermal imaging capability of the Landsat program. The TIRS bands are centered at roughly 10.9 and 12 μm (Bands 10 and 11 respectively). They have 100 m spatial resolution and image coincidently with the Operational Land Imager (OLI), also on-board L...
متن کاملGeothermal area detection using Landsat 8 operational land imager and thermal infrared sensor data in Ardabil province, Iran
GIS and remote sensing technique with using Landsat 8 images data are very important methods for detection of geothermal resources. In this study, Land Surface Temperature (LST) for Ardabil province in northwest of Iran, was derived with the use of Landsat 8 Operational Land Imager (OLI) of 30 m spatial resolution and Thermal Infrared Sensor (TIRS) data of 100 m spatial resolution. We consider ...
متن کاملEvaluation of Radiometric Performance for the Thermal Infrared Sensor Onboard Landsat 8
The radiometric performance of remotely-sensed images is important for the applications of such data in monitoring land surface, ocean and atmospheric status. One requirement placed on the Thermal Infrared Sensor (TIRS) onboard Landsat 8 was that the noise-equivalent change in temperature (NEΔT) should be ≤0.4 K at 300 K for its two thermal infrared bands. In order to optimize the use of TIRS d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Remote Sensing
دوره 6 شماره
صفحات -
تاریخ انتشار 2014