Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS.

نویسندگان

  • Joshua Godshaw
  • Helene Hopfer
  • Jenny Nelson
  • Susan E Ebeler
چکیده

Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the 63Cu:65Cu instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Levels of Five Heavy Metals in Human Urine and Sweat after Strenuous Exercise by ICP-MS

Inductively coupled plasma mass spectrometry (ICP-MS) was used to measure the levels of trace heavy metals in human urine and sweat, to compare the performance of ICP-MS using three sample processing methods, namely direct dilution, wet digestion, and microwave digestion. The results showed that the wet digestion ICP-MS method has the highest accuracy (relative standard deviation ≤10%) and is m...

متن کامل

Evaluation of the multi-element capabilities of collision/reaction cell inductively coupled plasma-mass spectrometry in wine analysis.

This work explores the multi-element capabilities of inductively coupled plasma-mass spectrometry with collision/reaction cell technology (CCT-ICP-MS) for the simultaneous determination of both spectrally interfered and non-interfered nuclides in wine samples using a single set of experimental conditions. The influence of the cell gas type (i.e. He, He+H2 and He+NH3), cell gas flow rate and sam...

متن کامل

Using ICP-MS to Determine the Effect of Storage Temperature and Packaging on the Trace Metal Composition of Wine Authors

The metal composition of finished wine is a function of the metals present in the grapes as well as those introduced by viticultural and enological practices [1]. Most research so far has focused on elemental profiling for the potential determination of the geographical origin of wine. However, in previous studies, the correlation between the trace element profile of vineyard soil and wine made...

متن کامل

Validation of a Simple Microwave-Assisted Acid Digestion Method Using Microvessels for Analysis of Trace Elements in Atmospheric PM2.5 in Monitoring and Fingerprinting Studies

Two microwave-assisted digestion procedures, followed by inductively coupled plasma mass spectrometry (ICP-MS) analysis, were evaluated for the determination of trace elements in fine atmospheric aerosols (PM2.5) for air monitoring purposes. The first procedure used 40%(v/v) HNO3 and a digestion program with a maximum temperature of 175 o C. The second digestion procedure provided the dissoluti...

متن کامل

Quantitative bioimaging by LA-ICP-MS: a methodological study on the distribution of Pt and Ru in viscera originating from cisplatin- and KP1339-treated mice.

Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to study the spatially-resolved distribution of ruthenium and platinum in viscera (liver, kidney, spleen, and muscle) originating from mice treated with the investigational ruthenium-based antitumor compound KP1339 or cisplatin, a potent, but nephrotoxic clinically-approved platinum-based anticancer drug. Method de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Molecules

دوره 22 10  شماره 

صفحات  -

تاریخ انتشار 2017