Membrane oxygenator heat exchanger failure detected by unique blood gas findings.
نویسنده
چکیده
Failure of components integrated into the cardiopulmonary bypass circuit, although rare, can bring about catastrophic results. One of these components is the heat exchanger of the membrane oxygenator. In this compartment, unsterile water from the heater cooler device is separated from the sterile blood by stainless steel, aluminum, or by polyurethane. These areas are glued or welded to keep the two compartments separate, maintaining sterility of the blood. Although quality control testing is performed by the manufacturer at the factory level, transport presents the real possibility for damage. Because of this, each manufacturer has included in the instructions for use a testing procedure for testing the integrity of the heat exchanger component. Water is circulated through the heat exchanger before priming and a visible check is made of the oxygenator bundle to check for leaks. If none are apparent, then priming of the oxygenator is performed. In this particular case, this procedure was not useful in detecting communication between the water and blood chambers of the oxygenator.
منابع مشابه
It is Time to Update Membrane Oxygenator Testing Standards and Their Instructions for Use.
Perfusion technology has evolved a great deal over the past 10 years. Heart–lung machines are more customizable. Oxygenators are increasingly including integrated arterial line filtration. Heater–cooler units are more likely to use very low pressure to achieve heat exchanger water flow. Electronic gas blenders (EGBs) are available for precise mixing of oxygenator sweep gas, which is particularl...
متن کاملA clinical evaluation of the Terumo Capiox SX18R hollow fiber oxygenator.
The Terumo Capiox SX18R is a commercially available, low prime, reverse phase, hollow fiber membrane oxygenator. The oxygenator consists of a 1.8 m2 microporous polypropylene hollow fiber bundle, a 2200 cm2 tubular stainless steel heat exchanger, and an open hard shell venous reservoir with integral cardiotomy filter. The Terumo Capiox SX18R oxygenator was evaluated to determine its clinical ox...
متن کاملPredicting oxygenator clinical performance from laboratory in-vitro testing.
Knowledge and predictability of oxygenator performance is vital to safe and effective conduct of cardiopulmonary bypass. The determination of oxygenator performance in the laboratory, however, is carried out under a strict set of conditions established by the Association for the Advancement of Medical Instrumentation (AAMI). This performance data is of limited value in the clinical setting wher...
متن کاملComparison of gaseous microemboli counts in arterial, simultaneous and venous heat exchange with a hollow fiber membrane oxygenator.
Potential sources of gaseous microemboli during cardiopulmonary bypass are varied. However, it is known that membrane oxygenators generate fewer gaseous microemboli than bubble oxygenators and that bubblers cannot utilize arterial heat exchange without generating significant gaseous microemboli during rewarming. A membrane oxygenator utilizing simultaneous gas and heat exchange raises the con...
متن کاملTemperature Monitoring During Ecmo: An in Vitro Study
Methods Experiment A. We analyzed heat dispersion of an ECMO circuit (Maquet Rotaflow PLS System) at 36 combinations of blood flow (BF 1-3-5 L/min), gas flow (GF 0-510 L/min) and set temperature (T set 36-37-38-39 °C). In any condition, heat dispersion was considered equal to the power (Watts) generated by the heat exchanger at the steady state, defined as stable temperature throughout the circ...