Effects of material properties of femoral hip components on bone remodeling.

نویسندگان

  • H Weinans
  • R Huiskes
  • H J Grootenboer
چکیده

Bone loss around femoral hip stems is one of the problems threatening the long-term fixation of uncemented stems. Many believe that this phenomenon is caused by reduced stresses in the bone (stress shielding). In the present study the mechanical consequences of different femoral stem materials were investigated using adaptive bone remodeling theory in combination with the finite element method. Bone-remodeling in the femur around the implant and interface stresses between bone and implant were investigated for fully bonded femoral stems. Cemented stems (cobalt-chrome or titanium alloy) caused less bone resorption and lower interface stresses than uncemented stems made from the same materials. The range of the bone resorption predicted in the simulation models was from 23% in the proximal medial cortex surrounding the cemented titanium alloy stem to 76% in the proximal medial cortex around the uncemented cobalt-chrome stem. Very little bone resorption was predicted around a flexible, uncemented "iso-elastic" stem, but the proximal interface stresses increased drastically relative to the stiffer uncemented stems composed of cobalt-chrome or titanium alloy. However, the proximal interface stress peak was reduced and shifted during the adaptive remodeling process. The latter was found particularly in the stiffer uncemented cobalt-chrome-molybdenum implant and less for the flexible iso-elastic implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anisotropic bone remodeling of a biomimetic metal-on-metal hip resurfacing implant.

Hip resurfacing (HR) is a highly attractive option for young and active patients. Some surgeons have advocated cementing the metaphyseal stem of the femoral component to improve fixation and survivorship of HR. However, extending component fixation to the metaphysis may promote femoral head strain shielding, which in turn may reduce survival of the femoral component. Replacing the metallic meta...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

Comparison of different distal designs of femoral components and their effects on bone remodeling in 1-stage bilateral total hip arthroplasty.

To evaluate the effects of distal design of a proximally coated femoral component on periprosthetic bone remodeling, we prospectively performed 21 one-stage bilateral total hip arthroplasties using a distally tapered and a distally cylindrical stem with the same proximal design, randomized to side. All hips showed good outcomes clinically and radiographically at the final follow-up, average of ...

متن کامل

Subchondral Insufficiency Fracture of the Femoral Head Treated with Core Decompression and Bone Void Filler Support

Subchondral insufficiency fracture of the femoral head (SIFFH) is characterized by acute onset hip pain without overt trauma. It appears as a low intensity band with bone marrow edema on T1-weighted MRI. The most common course of treatment is protected weight bearing for a period of several weeks. Total hip arthroplasty (THA) has been commonly used if the patient does not respond to the initial...

متن کامل

Revision Total Hip Arthroplasty Using a Modular Cementless Distal Fixation Prosthesis: the Zmr(®) Hip System. Clinical and Radiographic Analysis of 30 Cases.

OBJECTIVE To evaluate the clinical and radiographic results from 30 cases of revision of total hip arthroplasty using a modular cementless distal fixation prosthesis: the ZMR(®) Hip System. METHOD Between July 2005 and December 2008, 30 operations were performed, on 14 men and 14 women. Two male patients had bilateral surgery. The mean age was 59.2 years (29-81 years), with a mean follow-up o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 1992