Remote CMR 4D Flow Quantification of Pulmonary Flow
نویسندگان
چکیده
Background 4D MR flow has shown to have advantages over standard cardiac magnetic resonance (CMR), offering both anatomical and functional information in just a single acquisition. Pulmonary stenosis and pulmonary regurgitation are common problems in follow-up of patients with congenital heart disease. In this study we tested flow quantification at the level of the pulmonary valve (forward and backward flow, regurgitation fraction and peak systolic velocity) using a cloudbased software platform fully integrated with correction for eddy currents, Maxwell phase effects and gradient field non-linearity, visualization of the flow and anatomy, and flow quantification. Standard planar phase contrast CMR was used as a reference.
منابع مشابه
Atlas-based analysis of 4D flow CMR: Automated vessel segmentation and flow quantification
BACKGROUND Flow volume quantification in the great thoracic vessels is used in the assessment of several cardiovascular diseases. Clinically, it is often based on semi-automatic segmentation of a vessel throughout the cardiac cycle in 2D cine phase-contrast Cardiovascular Magnetic Resonance (CMR) images. Three-dimensional (3D), time-resolved phase-contrast CMR with three-directional velocity en...
متن کاملNon-invasive assessment of cardiac function and pulmonary vascular resistance in an canine model of acute thromboembolic pulmonary hypertension using 4D flow cardiovascular magnetic resonance
BACKGROUND The purpose of this study was to quantify right (RV) and left (LV) ventricular function, pulmonary artery flow (QP), tricuspid valve regurgitation velocity (TRV), and aorta flow (QS) from a single 4D flow cardiovascular magnetic resonance (CMR) (time-resolved three-directionally motion encoded CMR) sequence in a canine model of acute thromboembolic pulmonary hypertension (PH). METH...
متن کاملTricuspid flow and regurgitation in congenital heart disease and pulmonary hypertension: comparison of 4D flow cardiovascular magnetic resonance and echocardiography
BACKGROUND Tricuspid valve (TV) regurgitation (TR) is a common complication of pulmonary hypertension and right-sided congenital heart disease, associated with increased morbidity and mortality. Estimation of TR severity by echocardiography and conventional cardiovasvular magnetic resonance (CMR) is not well validated and has high variability. 4D velocity-encoded (4D-flow) CMR was used to measu...
متن کاملHemodynamic evaluation in patients with transposition of the great arteries after the arterial switch operation: 4D flow and 2D phase contrast cardiovascular magnetic resonance compared with Doppler echocardiography
BACKGROUND Peak velocity measurements are used to evaluate the significance of stenosis in patients with transposition of the great arteries after the arterial switch operation (TGA after ASO). 4D flow cardiovascular magnetic resonance (CMR) provides 3-directional velocity encoding and full volumetric coverage of the great arteries and may thus improve the hemodynamic evaluation in these patien...
متن کاملAnalysis of right heart flow patterns in repaired Tetralogy of Fallot with 4D flow-sensitive MRI
Introduction Cardiac MRI (CMR) is used to follow patients after TOF repair to assess pulmonary regurgitation (PR), pulmonary stenosis (PS) and right ventricular (RV) function. 4D flow-sensitive MRI techniques enable visualization of complex flow patterns [1],[2]. With the ability to simultaneously acquire morphology and hemodynamics for visualization and quantification, they may improve evaluat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 18 شماره
صفحات -
تاریخ انتشار 2016