Endograft Sizing for Endovascular Aortic Repair and Incidence of Endoleak Type 1A

نویسندگان

  • Ruben V C Buijs
  • Clark J Zeebregts
  • Tineke P Willems
  • Tryfon Vainas
  • Ignace F J Tielliu
چکیده

OBJECTIVE In endovascular aortic aneurysm repair (EVAR), proximal type 1A endoleaks can occur as a result of hostile neck anatomy or over- or undersizing of the endograft. As the current standard is based on the diameter or average of the short and long axes in a central lumen reconstruction image, it can falter in irregularly shaped aortic necks. An alternative method is circumference-based, therefore minimizing the measurement error. In this study we aimed to assess the degree of discrepancy between both methods and the association of this discrepancy with the occurrence of endoleak type 1A. METHODS All patients with early (<30 days post-operative) endoleak type 1A after elective EVAR at our center between 2004 and 2016 were identified for a retrospective case-control study. Control patients were matched based on hostile neck anatomy, such as calcification, thrombus, reverse taper, and β-angulation. The aortic neck diameter was measured using the traditional, diameter-based method as well as an alternative method, based on the circumference of the aortic neck. RESULTS In 482 EVAR patients, 18 early endoleak type 1A cases were found (3.9%). After exclusion, 12 cases remained and 48 matching controls were found. No significant differences were found between the two measuring methods at any level below the renal arteries. The inter-observer variability was significant for the D(mean) (0.4 ± 1.69 mm, P = .02) and was larger than the D(circ) method (-0.1 ± 1.03 mm, P = .35). In only four out of 12 cases the endograft size was 10-20% larger than the D(mean) and D(circ) measurements. The differences between the diameter of the D(mean) and D(circ) and the chosen endograft were smaller for the case group (-8 ± 25.6% and -7 ± 24%) than for the control group. (-12.4 ± 12.4% and -11 ± 10.7%). CONCLUSION The difference between the D(mean) and D(circ) methods for aortic neck measurement was not large enough to play a significant role in the incidence of endoleak type 1A. Inadequate oversizing and considerable β-angulation of the aortic neck may have been the cause of endoleak type 1A in this population. Robust and well-investigated sizing methods are paramount for accurate endograft sizing and prevention of endoleak type 1A. Therefore the lack of studies in this field and a sizeable inter-observer variability do not justify the widespread reliance on the traditional diameter-based methods for endograft sizing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Hypovolemia on Aortic Dimensions

A ruptured thoracic aorta is a rare but lifethreatening condition requiring immediate intervention. Possible causes of a ruptured thoracic aorta are ruptured descending thoracic aneurysms, acute type B aortic dissections, penetrating aortic ulcers, and traumatic thoracic aortic injuries (TTAI). Thoracic endovascular aortic repair (TEVAR) offers an effective treatment for these acute thoracic ao...

متن کامل

Late lumen loss in thoracic aortic end graft after endovascular procedure of a traumatic pseudoaneurysm

We report the case of a 23-year-old woman who died due to endograft stenosis 20 months after thoracic endovascular aortic repair. The patient presented with the pseudocoarctation syndrome. Although angioplasty of stenosis endograft was successfully performed, severe metabolic complications were lethal.

متن کامل

Impact of dynamic computed tomographic angiography on endograft sizing for endovascular aneurysm repair.

PURPOSE To quantify dynamic changes in aortoiliac dimensions using dynamic electrocardiographically (ECG)-gated computed tomographic angiography (CTA) and to investigate any potential impact on preoperative endograft sizing in relation to observer variability. METHODS Dynamic ECG-gated CTA was performed in 18 patients with abdominal aortic aneurysms. Postprocessing resulted in 11 datasets per...

متن کامل

Aorto-enteric Fistula 15 Years After Uncomplicated Endovascular Aortic Repair with Unforeseen Onset of Endocarditis

INTRODUCTION Aorto-enteric fistula after endovascular aortic repair is an exceedingly rare but serious condition. REPORT A rare case of a fistula between the excluded aortic sac and the transverse colon 15 years after endovascular aortic repair is described. Onset was endocarditis without gastrointestinal haemorrhage, migration, endoleak, or aortic sac dilatation. The patient was successfully...

متن کامل

What is the significance of endoleaks and endotension.

Endovascular repair has been used over a decade as a treatment of abdominal aortic aneurysm, and has become a widely accepted treatment method with a low rate of perioperative complications. Endoleak, perigraft blood flow outside endograft but within aneurysmsac, has been intensively studied during the last 10 years of endovascular aneurysm repair (EVR). The natural history of aneurysms with en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016