Method for large-range structured light system calibration.

نویسندگان

  • Yatong An
  • Tyler Bell
  • Beiwen Li
  • Jing Xu
  • Song Zhang
چکیده

Structured light system calibration often requires the usage of a calibration target with a similar size as the field of view (FOV), which brings challenges to a large-range structured light system calibration since fabricating large calibration targets is difficult and expensive. This paper presents a large-range system calibration method that does not need a large calibration target. The proposed method includes two stages: (1) accurately calibrate intrinsics (i.e., focal lengths and principle points) at a near range where both the camera and projector are out of focus, and (2) calibrate the extrinsic parameters (translation and rotation) from camera to projector with the assistance of a low-accuracy, large-range three-dimensional (3D) sensor (e.g., Microsoft Kinect). We have developed a large-scale 3D shape measurement system with a FOV of 1120  mm×1900  mm×1000  mm. Experiments demonstrate our system can achieve measurement accuracy as high as 0.07 mm with a standard deviation of 0.80 mm by measuring a 304.8 mm diameter sphere. As a comparison, Kinect V2 only achieved mean error of 0.80 mm with a standard deviation of 3.41 mm for the FOV of measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct Sensor-oriented Calibration of the Projector in Coded Structured Light System

Today, close range photogrammetry is known as an accurate and automatic 3D geometric measurement method especially for 3D point features (targets), but unfortunately it needs human supervision for 3D surface measurement due to nature of image matching problem. Therefore, in the last decade, coded structured light technique surpasses as one of the main complementary automatic and precise 3D surf...

متن کامل

Optimal checkerboard selection for structured light system calibration

Structured light system calibration has been widely studied over the decades, and a variety of calibration approaches have been proposed. Among these methods, the flexible method using flat checkerboard is widely adopted. However, there is a lack of studies on selecting the optimal checker size for high accuracy calibration, whilst it is vital to understanding this factor. This paper presents a...

متن کامل

Calibration of Projector with Fixed Pattern and Large Distortion Lens in a Structured Light System

The most critical factor affects accuracy of a Structured Light System (SLS) is calibration. Camera calibration is easy to complete because of its extensive study. To simplify projector calibration, previous work models the projector as an inverse camera and tries to build similar 3D-2D mapping data for projector calibration. Achieved mapping data is directly fed to some classic two-step camera...

متن کامل

High-Resolution Structured Light Range Scanner with Automatic Calibration

In this work, we present a low-cost high-resolution structured light range scanner with automatic calibration, based on temporal stripe encoding. We present a novel single-step automatic active stereo calibration method, based on optimal backprojection estimation. We also present a method for estimating local fidelity of the range image and show how this information can be used to obtain sub-st...

متن کامل

Novel method for structured light system calibration

Peisen S. Huang, MEMBER SPIE State University of New York at Stony Brook Department of Mechanical Engineering Stony Brook, New York 11794 E-mail: [email protected] Abstract. System calibration, which usually involves complicated and time-consuming procedures, is crucial for any 3-D shape measurement system. In this work, a novel systematic method is proposed for accurate and quick cal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 55 33  شماره 

صفحات  -

تاریخ انتشار 2016